MétaCan
Menu
Back to cohort

Detectability and accuracy of computational measurements of in-silico and physical representations of enlarged perivascular spaces from magnetic resonance images

2023· article· en· W4389975776 on OpenAlexfundno aff
Roberto Duarte Coello, María del C. Valdés Hernández, Jaco J.M. Zwanenburg, M. van der Velden, Hugo J. Kuijf, Alberto De Luca, José Bernal Moyano, Lucia Ballerini, Francesca M. Chappell, Rosalind Brown, Geert Jan Biessels, Joanna M. Wardlaw

Bibliographic record

VenueJournal of Neuroscience Methods · 2023
Typearticle
Languageen
FieldNeuroscience
TopicCerebrospinal fluid and hydrocephalus
Canadian institutionsnot available
FundersMedical Research CouncilAlzheimer's SocietyUK Dementia Research InstituteFondation LeducqWeston Brain InstituteMrs Gladys Row Fogo Charitable Trust
KeywordsVoxelImaging phantomArtificial intelligenceOrientation (vector space)Computer scienceFilter (signal processing)Magnetic resonance imagingPattern recognition (psychology)IsotropyComputer visionMathematicsPhysicsNuclear medicineRadiologyMedicine

Abstract

fetched live from OpenAlex

BACKGROUND: Magnetic Resonance Imaging (MRI) visible perivascular spaces (PVS) have been associated with age, decline in cognitive abilities, interrupted sleep, and markers of small vessel disease. But the limits of validity of their quantification have not been established. NEW METHOD: We use a purpose-built digital reference object to construct an in-silico phantom for addressing this need, and validate it using a physical phantom. We use cylinders of different sizes as models for PVS. We also evaluate the influence of 'PVS' orientation, and different sets of parameters of the two vesselness filters that have been used for enhancing tubular structures, namely Frangi and RORPO filters, in the measurements' accuracy. RESULTS: PVS measurements in MRI are only a proxy of their true dimensions, as the boundaries of their representation are consistently overestimated. The success in the use of the Frangi filter relies on a careful tuning of several parameters. Alpha= 0.5, beta= 0.5 and c= 500 yielded the best results. RORPO does not have these requirements and allows detecting smaller cylinders in their entirety more consistently in the absence of noise and confounding artefacts. The Frangi filter seems to be best suited for voxel sizes equal or larger than 0.4 mm-isotropic and cylinders larger than 1 mm diameter and 2 mm length. 'PVS' orientation did not affect measurements in data with isotropic voxels. COMPARISON WITH EXISTENT METHODS: Does not apply. CONCLUSIONS: The in-silico and physical phantoms presented are useful for establishing the validity of quantification methods of tubular small structures.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.008
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.495
Threshold uncertainty score0.918

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.008
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.088
GPT teacher head0.401
Teacher spread0.314 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations15
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Neuroscience MethodsSame topicCerebrospinal fluid and hydrocephalusFrench-language works237,207