MétaCan
Menu
Back to cohort
Record W4390404629 · doi:10.1002/mrm.29975

Tensor‐valued diffusion <scp>MRI</scp> of human acute stroke

2023· article· en· W4390404629 on OpenAlexafffund
Mi Zhou, Robert Stobbe, Filip Szczepankiewicz, Matthew D. Budde, Brian Buck, Mahesh Kate, Mar Lloret, Paige Fairall, Kenneth Butcher, Ashfaq Shuaib, Derek Emery, Markus Nilsson, Carl‐Fredrik Westin, Christian Beaulieu

Bibliographic record

VenueMagnetic Resonance in Medicine · 2023
Typearticle
Languageen
FieldMedicine
TopicAdvanced Neuroimaging Techniques and Applications
Canadian institutionsUniversity of Alberta
FundersChina Scholarship CouncilCanada Research ChairsMedical College of WisconsinHeart and Stroke Foundation of Canada
KeywordsDiffusion MRIFractional anisotropyWhite matterAnisotropyDiffusionIsotropyMonte Carlo methodNuclear magnetic resonanceChemistryPhysicsMedicineMagnetic resonance imagingMathematicsRadiologyStatisticsOpticsQuantum mechanics

Abstract

fetched live from OpenAlex

Abstract Purpose Tensor‐valued diffusion encoding can disentangle orientation dispersion and subvoxel anisotropy, potentially offering insight into microstructural changes after cerebral ischemia. The purpose was to evaluate tensor‐valued diffusion MRI in human acute ischemic stroke, assess potential confounders from diffusion time dependencies, and compare to Monte Carlo diffusion simulations of axon beading. Methods Linear (LTE) and spherical (STE) b‐tensor encoding with inherently different effective diffusion times were acquired in 21 acute ischemic stroke patients between 3 and 57 h post‐onset at 3 T in 2.5 min. In an additional 10 patients, STE with 2 LTE yielding different effective diffusion times were acquired for comparison. Diffusional variance decomposition (DIVIDE) was used to estimate microscopic anisotropy (μFA), as well as anisotropic, isotropic, and total diffusional variance (MKA, MKI, MKT). DIVIDE parameters, and diffusion tensor imaging (DTI)‐derived mean diffusivity and fractional anisotropy (FA) were compared in lesion versus contralateral white matter. Monte Carlo diffusion simulations of various cylindrical geometries for all b‐tensor protocols were used to interpret parameter measurements. Results MD was ˜40% lower in lesions for all LTE/STE protocols. The DIVIDE parameters varied with effective diffusion time: higher μFA and MKA in lesion versus contralateral white matter for STE with longer effective diffusion time LTE, whereas the shorter effective diffusion time LTE protocol yielded lower μFA and MKA in lesions. Both protocols, regardless of diffusion time, were consistent with simulations of greater beading amplitude and intracellular volume fraction. Conclusion DIVIDE parameters depend on diffusion time in acute stroke but consistently indicate neurite beading and larger intracellular volume fraction.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.053
GPT teacher head0.366
Teacher spread0.313 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAdvanced Neuroimaging Techniques and ApplicationsFrench-language works237,207