A Fault-tolerant Scheme for Switching Devices in Current-Fed Dual-Active-Bridge Converter
Bibliographic record
Abstract
Current-fed dual active bridge (CF-DAB) DC/DC converters have been widely used in renewable energy applications. The reliability of the CF-DAB converters attracts lots of attention. However, so far, the fault-tolerant schemes for switching device failures are mainly reported on three-phase CF-DAB converters, and limited literature focuses on the single-phase structure due to the low device redundancy. To address this important issue, a fault-tolerance scheme is proposed for the switching devices in the single-phase CF-DAB converter in this paper. With the proposed scheme, the CF-DAB converter can maintain the power transfer capability even if the two upper switching devices in the current-fed full bridge fail. Subsequently, this paper elaborates on the fault-tolerant converter characters and corresponding control strategies. Finally, the experimental results verify the performance of the proposed fault-tolerant scheme.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.001 | 0.000 |
| Science and technology studies | 0.001 | 0.000 |
| Scholarly communication | 0.000 | 0.001 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".