MétaCan
Menu
Back to cohort
Record W4390450557 · doi:10.1021/acs.analchem.3c04354

Rapid Analysis of Fentanyl and Fentanyl Analogues from Whole Blood Using SPME Coupled to the Microfluidic Open Interface

2023· article· en· W4390450557 on OpenAlexafffund
Emir Nazdrajić, Daniel Rickert, Janusz Pawliszyn

Bibliographic record

VenueAnalytical Chemistry · 2023
Typearticle
Languageen
FieldPharmacology, Toxicology and Pharmaceutics
TopicForensic Toxicology and Drug Analysis
Canadian institutionsUniversity of Waterloo
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsFentanylChemistryChromatographyReproducibilityExtraction (chemistry)Sample preparationMicrofluidicsDetection limitPharmacologyNanotechnologyMaterials science

Abstract

fetched live from OpenAlex

Fentanyl and its analogues are potent opioids that pose a significant threat to society. Over the last several years, considerable focus has been on the concerning trend of increasing fentanyl usage among drug users. Fentanyl analogues are mainly synthesized to evade analytical detection or increase their potency; thus, very low concentrations are sufficient to achieve a therapeutic effect. In an effort to help combat the synthetic opioid epidemic, developing targeted mass spectrometric methods for quantifying fentanyl and its analogues at ultralow concentrations is incredibly important. Most methods used to analyze fentanyl and its analogues from whole blood require manual sample preparation protocols (solid-phase extraction or liquid–liquid extraction), followed by chromatographic separation and mass spectrometric detection. The main disadvantages of these methods are the tedious sample preparation workflows, resulting in lengthy analysis times. To mitigate these issues, we present a targeted method capable of analyzing 96 samples containing fentanyl, several fentanyl analogues, and a common fentanyl (analogue) precursor simultaneously in 2.4 min per sample. This is possible by using a high-throughput solid phase microextraction workflow on the Concept96 autosampler followed by manual coupling of solid-phase microextraction fibers to the microfluidic open interface for tandem mass spectrometry analysis. Our quantitative method is capable of extremely sensitive analysis, with limits of quantification ranging from 0.002 to 0.031 ng mL –1 and linearity ranging from 0.010 to 25.0 ng mL –1 . The method shows very good reproducibility (1–18%), accuracy (81–100%) of calibration and validation points, and good interday reproducibility (6–15%).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.321
Threshold uncertainty score0.998

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.002
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0010.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.107
GPT teacher head0.422
Teacher spread0.316 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicForensic Toxicology and Drug AnalysisFrench-language works237,207