MétaCan
Menu
Back to cohort
Record W4390670650 · doi:10.1177/08465371231220885

Deep Learning for Pneumothorax Detection on Chest Radiograph: A Diagnostic Test Accuracy Systematic Review and Meta Analysis

2024· review· en· W4390670650 on OpenAlexaff
Benjamin D. Katzman, Mostafa Alabousi, Nabil Islam, Nanxi Zha, Michael N. Patlas

Bibliographic record

VenueCanadian Association of Radiologists Journal · 2024
Typereview
Languageen
FieldMedicine
TopicCOVID-19 diagnosis using AI
Canadian institutionsUniversity of OttawaUniversity of TorontoMcMaster University
Fundersnot available
KeywordsMedicineChest radiographPneumothoraxConfidence intervalMedical diagnosisMeta-analysisRadiographyRadiologyContingency tableMedical physicsMachine learningInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: Pneumothorax is a common acute presentation in healthcare settings. A chest radiograph (CXR) is often necessary to make the diagnosis, and minimizing the time between presentation and diagnosis is critical to deliver optimal treatment. Deep learning (DL) algorithms have been developed to rapidly identify pathologic findings on various imaging modalities. PURPOSE: The purpose of this systematic review and meta-analysis was to evaluate the overall performance of studies utilizing DL algorithms to detect pneumothorax on CXR. METHODS: A study protocol was created and registered a priori (PROSPERO CRD42023391375). The search strategy included studies published up until January 10, 2023. Inclusion criteria were studies that used adult patients, utilized computer-aided detection of pneumothorax on CXR, dataset was evaluated by a qualified physician, and sufficient data was present to create a 2 × 2 contingency table. Risk of bias was assessed using the QUADAS-2 tool. Bivariate random effects meta-analyses and meta-regression modeling were performed. RESULTS: Twenty-three studies were selected, including 34 011 patients and 34 075 CXRs. The pooled sensitivity and specificity were 87% (95% confidence interval, 81%, 92%) and 95% (95% confidence interval, 92%, 97%), respectively. The study design, use of an institutional/public data set and risk of bias had no significant effect on the sensitivity and specificity of pneumothorax detection. CONCLUSIONS: The relatively high sensitivity and specificity of pneumothorax detection by deep-learning showcases the vast potential for implementation in clinical settings to both augment the workflow of radiologists and assist in more rapid diagnoses and subsequent patient treatment.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.111
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch, Meta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.798
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0040.111
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0070.004
Bibliometrics0.0030.002
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.053
GPT teacher head0.359
Teacher spread0.306 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueCanadian Association of Radiologists JournalSame topicCOVID-19 diagnosis using AIFrench-language works237,207