MétaCan
Menu
← Back to cohort
Record W4390793238 · doi:10.1111/cid.13302

In vitro and in vivo accuracy of autonomous robotic vs. fully guided static computer‐assisted implant surgery

2024· article· en· W4390793238 on OpenAlexvenueno aff
He Jin, Qinmeng Zhang, Xueting Wang, Mengdie Fu, Hui Zhang, Luyao Song, Rui Pu, Zhiwei Jiang, Guoli Yang

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2024
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
FundersNational Natural Science Foundation of China
KeywordsImplantMedicineCone beam computed tomographyIn vivoDentistryMann–Whitney U testOrthodonticsNuclear medicineMathematicsSurgeryComputed tomographyInternal medicine

Abstract

fetched live from OpenAlex

OBJECTIVES: To assess the accuracy of autonomous robotic and fully guided static computer-assisted implant surgery (sCAIS) performed on models and patients. MATERIALS AND METHODS: This study was divided into in vitro and in vivo sections. In vitro, 80 operators were assigned to two groups randomly. Forty operators performed forty autonomous robotic implant (ARI group) surgeries and the remaining forty operators carried out forty fully guided sCAIS (FGI group) surgeries on maxillary models, respectively. Each operator placed an implant in one maxillary model. In vivo, 60 patients with 113 implants from 2019 to 2023 (ARI group: 32 patients, 58 implants; FGI group: 28 patients, 55 implants) receiving implant surgeries were incorporated in this retrospective research. The preoperative and postoperative cone beam computer tomographs (CBCTs) were utilized to estimate the linear deviations and angular deviations in two-dimensional (2D) and three-dimensional (3D) space. The Pearson's chi-square test, Shapiro-Wilk test, Student's t test, Mann-Whitney U test and mixed models were applied, and p <0.05 was considered statistically significant. RESULTS: In vitro, a total of 80 implants were enrolled and significant differences were found between the two groups (p < 0.001): The 3D deviation at the platform of ARI and FGI group was 0.58 ± 0.60 mm and 1.50 ± 1.46 mm, respectively, at the apex was 0.58 ± 0.60 mm and 1.78 ± 1.35 mm, respectively, and angle was 1.01 ± 0.87° and 2.93 ± 1.59°, respectively. Also, except for mesiodistal deviation at the implant platform, the rest linear and angular deviations in the ARI group were significantly lower than those in the FGI group in 2D space (p < 0.001). In vivo, a significantly lower mean of angular deviation (0.95 ± 0.50°, p < 0.001) and the linear deviation at both platform (0.45 ± 0.28 mm, p < 0.001) and apex (0.47 ± 0.28 mm, p < 0.001) were observed in ARI group when compared to the FGI group (4.31 ± 2.60°; 1.45 ± 1.27 mm; 1.77 ± 1.14 mm). CONCLUSIONS: The use of autonomous robotic technology showed significantly higher accuracy than the fully guided sCAIS.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.012

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.005
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.140
GPT teacher head0.464
Teacher spread0.324 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations26
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related Research→Same topicDental Implant Techniques and Outcomes→French-language works237,207→