MétaCan
Menu
Back to cohort
Record W4390795245 · doi:10.1016/j.jocmr.2023.100004

Inter-scanner comparability of Z-scores for native myocardial T1 and T2 mapping

2024· article· en· W4390795245 on OpenAlexafffund
Saad Razzaq, Leila Haririsanati, Katerina Eyre, Ria Garg, Michael Chetrit, Matthias G. Friedrich

Bibliographic record

VenueJournal of Cardiovascular Magnetic Resonance · 2024
Typearticle
Languageen
FieldMedicine
TopicCardiac Imaging and Diagnostics
Canadian institutionsMcGill UniversityMcGill University Health Centre
FundersMcGill University Health CentreMcGill University
KeywordsComparabilityMedicineInterpretabilityGeneralizability theoryAngiologyScannerNuclear medicineStudent's t-testMagnetic resonance imagingLimits of agreementContrast (vision)StatisticsMedical physicsArtificial intelligenceRadiologyComputer scienceMathematicsStatistical significanceInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: Cardiovascular Magnetic Resonance (CMR) native T1 and T2 mapping serve as robust, contrast-agent-free diagnostic tools, but hardware- and software-specific sources of variability limit the generalizability of data across CMR platforms, consequently limiting the interpretability of patient-specific parametric data. Z-scores are used to describe the relationship of observed values to the mean results as obtained in a sufficiently large normal sample. They have been successfully used to describe the severity of quantifiable abnormalities in medicine, specifically in children and adolescents. The objective of this study was to observe whether z-scores can improve the comparability of T1 and T2 mapping values across CMR scanners, field strengths, and sequences from different vendors in the same participant rather than different participants (as seen in previous studies). METHODS: Fifty-one healthy volunteers (26 men/25 women, mean age = 43 ± 13.51) underwent three CMR exams on three different scanners, using a Modified Look-Locker Inversion Recovery (MOLLI) 5-(3)- 3 sequence to quantify myocardial T1. For T2 mapping, a True Fast Imaging with steady-state free precession (TRUFI) sequence was used on a 3 T Skyra™ (Siemens), and a T2 Fast Spin Echo (FSE) sequence was used on 1.5 T Artist™ (GE) and 3.0 T Premier™ (GE) scanners. The averages of basal and mid-ventricular short axis slices were used to derive means and standard deviations of global mapping values. We used intra-class comparisons (ICC), repeated measures ANOVA, and paired Student's t-tests for statistical analyses. RESULTS: : p = 0.985). Furthermore, when images were not corrected for motion, T1 z-scores showed significant inter-scanner variability (p < 0.001), resolved by motion correction. CONCLUSION: Employing z-scores for reporting myocardial T1 and T2 removes the variation of quantitative mapping results across different MRI systems and field strengths, improving the clinical utility of myocardial tissue characterization in patients with suspected myocardial disease.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.952
Threshold uncertainty score0.534

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.002
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.267
Teacher spread0.251 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Cardiovascular Magnetic ResonanceSame topicCardiac Imaging and DiagnosticsFrench-language works237,207