MétaCan
Menu
Back to cohort
Record W4390839589 · doi:10.1002/acn3.51959

Consistency of electrical source imaging in presurgical evaluation of epilepsy across different vigilance states

2024· article· en· W4390839589 on OpenAlexafffund
Tamir Avigdor, Chifaou Abdallah, Jawata Afnan, Zhengchen Cai, Saba Rammal, Christophe Grova, Birgit Frauscher

Bibliographic record

VenueAnnals of Clinical and Translational Neurology · 2024
Typearticle
Languageen
FieldMedicine
TopicEpilepsy research and treatment
Canadian institutionsConcordia UniversityMcGill UniversityMontreal Neurological Institute and Hospital
FundersCanadian Institutes of Health ResearchMontreal Neurological Institute and HospitalSavoy Foundation
KeywordsVigilance (psychology)IctalElectroencephalographyWakefulnessMedicineEpilepsyAudiologyAmplitudeAnesthesiaNeurosciencePsychologyPsychiatryPhysicsOptics

Abstract

fetched live from OpenAlex

OBJECTIVE: The use of electrical source imaging (ESI) in assessing the source of interictal epileptic discharges (IEDs) is gaining increasing popularity in presurgical work-up of patients with drug-resistant focal epilepsy. While vigilance affects the ability to locate IEDs and identify the epileptogenic zone, we know little about its impact on ESI. METHODS: We studied overnight high-density electroencephalography recordings in focal drug-resistant epilepsy. IEDs were marked visually in each vigilance state, and examined in the sensor and source space. ESIs were calculated and compared between all vigilance states and the clinical ground truth. Two conditions were considered within each vigilance state, an unequalized and an equalized number of IEDs. RESULTS: The number, amplitude, and duration of IEDs were affected by the vigilance state, with N3 sleep presenting the highest number, amplitude, and duration for both conditions (P < 0.001), while signal-to-noise ratio only differed in the unequalized condition (P < 0.001). The vigilance state did not affect channel involvement (P > 0.05). ESI maps showed no differences in distance, quality, extent, or maxima distances compared to the clinical ground truth for both conditions (P > 0.05). Only when an absolute reference (wakefulness) was used, the channel involvement (P < 0.05) and ESI source extent (P < 0.01) were impacted during rapid-eye-movement (REM) sleep. Clustering of amplitude-sensitive and -insensitive ESI maps pointed to amplitude rather than the spatial profile as the driver (P < 0.05). INTERPRETATION: IED ESI results are stable across vigilance states, including REM sleep, if controlled for amplitude and IED number. ESI is thus stable and invariant to the vigilance state.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.006
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.147
GPT teacher head0.486
Teacher spread0.339 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueAnnals of Clinical and Translational NeurologySame topicEpilepsy research and treatmentFrench-language works237,207