MétaCan
Menu
Back to cohort
Record W4390973582 · doi:10.1038/s41598-024-51864-4

Ultrasensitive detection of vital biomolecules based on a multi-purpose BioMEMS for Point of care testing: digoxin measurement as a case study

2024· article· en· W4390973582 on OpenAlexaff
Fahimeh Marvi, Kian Jafari, Mahmoud Shahabadi, Maryam Tabarzad, Fatemeh Ghorbani-Bidkorpeh, Taha Azad

Bibliographic record

VenueScientific Reports · 2024
Typearticle
Languageen
FieldPhysics and Astronomy
TopicMechanical and Optical Resonators
Canadian institutionsInstitut interdisciplinaire d'innovation technologiqueCentre Hospitalier Universitaire de SherbrookeUniversité de Sherbrooke
Fundersnot available
KeywordsAnalyteRepeatabilityPoint of careTherapeutic drug monitoringDetection limitBiomedical engineeringBiosensorMaterials scienceComputer scienceMicroelectromechanical systemsReproducibilityBiomoleculeNanotechnologyChromatographyChemistryDrugMedicinePharmacologyPathology

Abstract

fetched live from OpenAlex

Abstract Rapid and label-free detection of very low concentrations of biomarkers in disease diagnosis or therapeutic drug monitoring is essential to prevent disease progression in Point of Care Testing. For this purpose, we propose a multi-purpose optical Bio-Micro-Electro-Mechanical-System (BioMEMS) sensing platform which can precisely measure very small changes of biomolecules concentrations in plasma-like buffer samples. This is realized by the development of an interferometric detection method on highly sensitive MEMS transducers (cantilevers). This approach facilitates the precise analysis of the obtained results to determine the analyte type and its concentrations. Furthermore, the proposed multi-purpose platform can be used for a wide range of biological assessments in various concentration levels by the use of an appropriate bioreceptor and the control of its coating density on the cantilever surface. In this study, the present system is prepared for the identification of digoxin medication in its therapeutic window for therapeutic drug monitoring as a case study. The experimental results represent the repeatability and stability of the proposed device as well as its capability to detect the analytes in less than eight minutes for all samples. In addition, according to the experiments carried out for very low concentrations of digoxin in plasma-like buffer, the detection limit of LOD = 300 fM and the maximum sensitivity of S = 5.5 × 10 12 AU/M are achieved for the implemented biosensor. The present ultrasensitive multi-purpose BioMEMS sensor can be a fully-integrated, cost-effective device to precisely analyze various biomarker concentrations for various biomedical applications.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.051
Threshold uncertainty score0.417

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.034
GPT teacher head0.292
Teacher spread0.258 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueScientific ReportsSame topicMechanical and Optical ResonatorsFrench-language works237,207