MétaCan
Menu
Back to cohort
Record W4390984794 · doi:10.1002/acm2.14269

Four‐dimensional treatment planning strategies for dynamic tumor tracking

2024· article· en· W4390984794 on OpenAlexaff
Emilie E. Carpentier, Ronan McDermott, Marie‐Laure Camborde, Tania Karan, Alanah Bergman, Ante Mestrovic

Bibliographic record

VenueJournal of Applied Clinical Medical Physics · 2024
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsBC Cancer AgencySpinal Cord Injury BCUniversity of British Columbia
Fundersnot available
KeywordsRadiation treatment planningAperture (computer memory)Nuclear medicineRadiation therapyComputer scienceDosimetrySortingMultileaf collimatorTracking (education)MedicinePhysicsRadiologyAlgorithm

Abstract

fetched live from OpenAlex

Abstract Introduction Dynamic tumor tracking (DTT) is a motion management technique where the radiation beam follows a moving tumor in real time. Not modelling DTT beam motion in the treatment planning system leaves an organ at risk (OAR) vulnerable to exceeding its dose limit. This work investigates two planning strategies for DTT plans, the “Boolean OAR Method” and the “Aperture Sorting Method,” to determine if they can successfully spare an OAR while maintaining sufficient target coverage. Materials and methods A step‐and‐shoot intensity modulated radiation therapy (sIMRT) treatment plan was re‐optimized for 10 previously treated liver stereotactic ablative radiotherapy patients who each had one OAR very close to the target. Two planning strategies were investigated to determine which is more effective at sparing an OAR while maintaining target coverage: (1) the “Boolean OAR Method” created a union of an OAR's contours from two breathing phases (exhale and inhale) on the exhale phase (the planning CT) and protected this combined OAR during plan optimization, (2) the “Aperture Sorting Method” assigned apertures to the breathing phase where they contributed the least to an OAR's maximum dose. Results All 10 OARs exceeded their dose constraints on the original plan four‐dimensional (4D) dose distributions and average target coverage was V 100% = 91.3% ± 2.9% (ranging from 85.1% to 94.8%). The “Boolean OAR Method” spared 7/10 OARs, and mean target coverage decreased to V 100% = 87.1% ± 3.8% (ranging from 80.7% to 93.7%). The “Aperture Sorting Method” spared 9/10 OARs and the mean target coverage remained high at V 100% = 91.7% ± 2.8% (ranging from 84.9% to 94.5%). Conclusions 4D planning strategies are simple to implement and can improve OAR sparing during DTT treatments. The “Boolean OAR Method” improved sparing of OARs but target coverage was reduced. The “Aperture Sorting Method” further improved sparing of OARs and maintained target coverage.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Theoretical or conceptual · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.891
Threshold uncertainty score0.619

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.048
GPT teacher head0.413
Teacher spread0.365 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designTheoretical or conceptual
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Applied Clinical Medical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207