<i>Editorial Commentary:</i> Locking Plate Removal Is Safe and May Improve Function 1 Year After Medial Opening Wedge High Tibial Osteotomy
Bibliographic record
Abstract
The development of angular stable locking late fixation in realignment osteotomy has resulted in the ability to be more aggressive with weight bearing and rehabilitation after high tibial osteotomy. One of the downsides of some of these plate fixators is the degree of soft-tissue irritation and discomfort that can be experienced by many patients, resulting in the need for hardware removal. Studies have shown greater than 50% of patients requiring hardware removal with no resulting loss of correction, although there may be cultural reasons for the higher number, not solely attributable to the symptom profile. It is encouraging to see that after 1 year postoperatively, hardware removal after high tibial osteotomy not only is safe but also results in a clinically important improvement in pain and function, with progressive bone healing out to 2 years.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.004 | 0.021 |
| Meta-epidemiology (narrow) | 0.003 | 0.001 |
| Meta-epidemiology (broad) | 0.003 | 0.002 |
| Bibliometrics | 0.003 | 0.002 |
| Science and technology studies | 0.003 | 0.002 |
| Scholarly communication | 0.005 | 0.004 |
| Open science | 0.004 | 0.001 |
| Research integrity | 0.021 | 0.020 |
| Insufficient payload (model declined to judge) | 0.009 | 0.010 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".