A modified intraventricular balloon method for functional assessment of hearts from donation after circulatory death
Bibliographic record
Abstract
Objective Functional assessment of hearts during ex-vivo heart perfusion is not well-established. Conventional intraventricular balloon methods for large animals sacrifice the mitral valve. This study assessed the effectiveness of the modified intraventricular balloon method in comparison with other modalities used during working mode in juvenile pigs. Methods Following asphyxia circulatory arrest, hearts were ischemic for 15 minutes and then reperfused on an ex-vivo device for 2 hours before switching to working mode. Left ventricular pressure was continuously measured during reperfusion by a saline-filled balloon fixated in the left atrium. Spearman Correlation Coefficients with linear regression lines with confidence intervals were analyzed. Results Maximum dp/dt at 90 minutes of reperfusion and minimum dp/dt at 60 minutes of reperfusion showed a moderate positive correlation to that in working mode, respectively (Rs = 0.61, P = .04 and Rs = 0.60, P = .04). At 60 minutes of reperfusion, minimum dp/dt showed moderate positive correlation to tau (Rs = 0.52, P = .08). Myocardial oxygen consumption during reperfusion consistently decreased at least 30% compared to working mode (at 90 minutes as the highest during reperfusion, 3.3 ± 0.8; in working mode, 5.6 ± 1.4, mLO 2 /min/100 g, P < .001). Conclusions Functional parameters of contractility and relaxation measured during reperfusion by the modified balloon method showed significant correlations to respective parameters in working mode. This mitral valve sparing technique can be used to predict viability and ventricular function in the early phase of ex-vivo heart perfusion without loading the heart during working mode.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".