MétaCan
Menu
Back to cohort
Record W4391134846 · doi:10.1123/jmpb.2023-0027

Criterion Validity of Accelerometers in Determining Knee-Flexion Angles During Sitting in a Laboratory Setting

2024· article· en· W4391134846 on OpenAlexaff
Yanlin Wu, Myles W. O’Brien, Alexander Peddle, W. Seth Daley, Beverly D. Schwartz, Derek S. Kimmerly, Ryan J. Frayne

Bibliographic record

VenueJournal for the Measurement of Physical Behaviour · 2024
Typearticle
Languageen
FieldMedicine
TopicSports Performance and Training
Canadian institutionsNova Scotia Health AuthorityDalhousie University
Fundersnot available
KeywordsAccelerometerSittingPhysical medicine and rehabilitationKnee flexionCriterion validityOrthodonticsPhysical therapyComputer scienceMedicineMathematicsStatisticsConstruct validityPsychometrics

Abstract

fetched live from OpenAlex

Introduction : Device-based monitors often classify all sedentary positions as the sitting posture, but sitting with bent or straight legs may exhibit unique physiological and biomechanical effects. The classifications of the specific nuances of sitting have not been understood. The purpose of this study was to validate a dual-monitor approach from a trimonitor configuration measuring knee-flexion angles compared to motion capture (criterion) during sitting in laboratory setting. Methods : Nineteen adults (12 ♀ , 24 ± 4 years) wore three activPALs (torso, thigh, tibia) while 14 motion capture cameras simultaneously tracked 15 markers located on bony landmarks. Each participant completed a 45-s supine resting period and eight, 45-s seated trials at different knee flexion angles (15° increment between 0° and 105°, determined via goniometry), followed by 15 s of standing. Validity was assessed via Friedman’s test (adjusted p value = .006), mean absolute error, Bland–Altman analyses, equivalence testing, and intraclass correlation. Results : Compared to motion capture, the calculated angles from activPALs were not different during 15°–90° (all, p ≥ .009), underestimated at 105° ( p = .002) and overestimated at 0°, as well as the supine position (both, p < .001). Knee angles between 15° and 105° exhibited a mean absolute error of ∼5°, but knee angles <15° exhibited larger degrees of error (∼10°). A proportional (β = −0.12, p < .001) bias was observed, but a fixed (0.5° ± 1.7°, p = .405) bias did not exist. In equivalence testing, the activPALs were statistically equivalent to motion capture across 30°–105°. Strong agreement between the activPALs and motion capture was observed (intraclass correlation = .97, p < .001). Conclusions : The usage of a three-activPAL configuration detecting seated knee-flexion angles in free-living conditions is promising.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.189
Threshold uncertainty score0.361

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.081
GPT teacher head0.347
Teacher spread0.266 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueJournal for the Measurement of Physical BehaviourSame topicSports Performance and TrainingFrench-language works237,207