MétaCan
Menu
Back to cohort
Record W4391281185 · doi:10.1002/acm2.14272

Intraoperative radiation therapy with 50 kV x‐rays: A multi‐institutional review

2024· review· en· W4391281185 on OpenAlexaff
Anil Sethi, Sébastien Gros, P. Brodin, Beth Ghavidel, X. Chai, Marija Popović, Wolfgang A. Tomé, Samuel Trichter, Xiaofeng Yang, Hualin Zhang, Valery Uhl

Bibliographic record

VenueJournal of Applied Clinical Medical Physics · 2024
Typereview
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsMcGill University Health Centre
Fundersnot available
KeywordsQuality assuranceMedical physicsDosimetryRadiation treatment planningMedicineNuclear medicineIntraoperative radiation therapyDosimeterWorkflowElectromagnetic shieldingRadiation therapyComputer sciencePhysicsRadiology

Abstract

fetched live from OpenAlex

This report covers clinical implementation of a low kV intraoperative radiation therapy (IORT) program with the INTRABEAM® System (Carl Zeiss Meditec AG, Jena, Germany). Based on collective user experience from eight institutions, we discuss best methods of INTRABEAM quality assurance (QA) tests, commissioning measurements, clinical workflow, treatment planning, and potential avenues for research. The guide provides pertinent background information and clinical justification for IORT. It describes the INTRABEAM system and commissioning measurements along with a TG100 risk management analysis to ensure safety and accuracy of the IORT program. Following safety checks, dosimetry measurements are performed for verification of field flatness and symmetry, x-ray output, and depth dose. Also discussed are dose linearity checks, beam isotropy, ion chamber measurements, calibration protocols, and in-vivo dosimetry with optically stimulated luminescence dosimeters OSLDs, and radiochromic film. Emphasis is placed on the importance of routine QA procedures (daily, monthly, and annual) performed at regular intervals for a successful IORT program. For safe and accurate dose delivery, tests of important components of IORT clinical workflow are emphasized, such as, dose prescription, pre-treatment QA, treatment setup, safety checks, radiation surveys, and independent checks of delivered dose. Challenges associated with in-vivo dose measurements are discussed, along with special treatment procedures and shielding requirements. The importance of treatment planning in IORT is reviewed with reference to a Monte Carlo-based commercial treatment planning system highlighting its main features and limitations. The report concludes with suggested topics for research including CT-based image-guided treatment planning and improved prescription dose accuracy. We hope that this multi-institutional report will serve as a guidance document on the clinical implementation and use of INTRABEAM IORT.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.009
metaresearch head score (Gemma)0.013
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.009
Threshold uncertainty score0.047

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0090.013
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0090.009
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.003

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.069
GPT teacher head0.443
Teacher spread0.374 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Applied Clinical Medical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207