Uptake behavior of polycyclic aromatic compounds during field calibrations of the XAD-based passive air sampler across seasons and locations
Bibliographic record
Abstract
Abstract. Polycyclic aromatic compounds (PACs) continue to demand attention due to their widespread presence and well-established health implications. Given that incomplete combustion is a major contributor to PACs and inhalation constitutes a crucial human exposure pathway, a comprehensive understanding of the concentrations, spatial distributions, and fates of a broad range of PACs in the atmosphere is important. Passive air samplers (PASs) are a commonly utilized technique for PAC sampling and monitoring. In this study, we present the results from two 1-year calibration experiments, one starting in summer and the other in winter, using a passive air sampler equipped with XAD resin as the sorbent (XAD-PAS). Throughout both experiments, PACs were consistently sorbed during the initial 6-month period. However, the sorbed amounts for many PACs exhibited a decrease after half a year of deployment. Three hypotheses to explain this phenomenon were explored, including the uptake of atmospheric particles, evaporation from the sorbent, and reactions with photo-oxidants. All had to be rejected based on the obtained data, additional laboratory experiments, and model results. Model simulations were further used to (i) confirm that a loss process must be invoked to explain the observed uptake behavior and (ii) estimate the kinetics of that loss process for different PACs. Sampling rates (SRs) for 28 PACs derived from the linearized uptake curves during the first 6 months of deployment were comparable to those of other semi-volatile organic compounds obtained during the same calibration experiment, and they also demonstrate a consistent negative correlation with volatility.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.001 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.001 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".