MétaCan
Menu
Back to cohort
Record W4391465702 · doi:10.1088/1361-6560/ad25c8

Material decomposition with a prototype photon-counting detector CT system: expanding a stoichiometric dual-energy CT method via energy bin optimization and K-edge imaging

2024· article· en· W4391465702 on OpenAlexafffund
Devon Richtsmeier, Pierre‐Antoine Rodesch, Kris Iniewski, Magdalena Bazalova‐Carter

Bibliographic record

VenuePhysics in Medicine and Biology · 2024
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsRedlen Technologies (Canada)University of Victoria
FundersBritish Columbia Knowledge Development FundNatural Sciences and Engineering Research Council of CanadaCanada Research ChairsCanada Foundation for Innovation
KeywordsImaging phantomEnergy (signal processing)Atomic numberDetectorEffective atomic numberPhoton countingDigital Enhanced Cordless TelecommunicationsPhysicsSubtractionMaterials scienceOpticsMathematicsComputer scienceAtomic physics

Abstract

fetched live from OpenAlex

Abstract Objective. Computed tomography (CT) has advanced since its inception, with breakthroughs such as dual-energy CT (DECT), which extracts additional information by acquiring two sets of data at different energies. As high-flux photon-counting detectors (PCDs) become available, PCD-CT is also becoming a reality. PCD-CT can acquire multi-energy data sets in a single scan by spectrally binning the incident x-ray beam. With this, K-edge imaging becomes possible, allowing high atomic number (high-Z) contrast materials to be distinguished and quantified. In this study, we demonstrated that DECT methods can be converted to PCD-CT systems by extending the method of Bourque et al (2014). We optimized the energy bins of the PCD for this purpose and expanded the capabilities by employing K-edge subtraction imaging to separate a high-atomic number contrast material. Approach. The method decomposes materials into their effective atomic number ( Z eff ) and electron density relative to water ( ρ e ). The model was calibrated and evaluated using tissue-equivalent materials from the RMI Gammex electron density phantom with known ρ e values and elemental compositions. Theoretical Z eff values were found for the appropriate energy ranges using the elemental composition of the materials. Z eff varied slightly with energy but was considered a systematic error. An ex vivo bovine tissue sample was decomposed to evaluate the model further and was injected with gold chloride to demonstrate the separation of a K-edge contrast agent. Main results. The mean root mean squared percent errors on the extracted Z eff and ρ e for PCD-CT were 0.76% and 0.72%, respectively and 1.77% and 1.98% for DECT. The tissue types in the ex vivo bovine tissue sample were also correctly identified after decomposition. Additionally, gold chloride was separated from the ex vivo tissue sample with K-edge imaging. Significance. PCD-CT offers the ability to employ DECT material decomposition methods, along with providing additional capabilities such as K-edge imaging.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.909
Threshold uncertainty score0.605

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.317
Teacher spread0.291 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2024
Admission routes2
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicAdvanced X-ray and CT ImagingFrench-language works237,207