MétaCan
Menu
Back to cohort
Record W4391530107 · doi:10.1016/j.recot.2024.01.023

[Artículo traducido] Clavo corto versus clavo largo en la fractura intertrocantérica de cadera: metaanálisis

2024· article· es· W4391530107 on OpenAlexaboutno aff
Pedro Doménech, Gonzalo Mariscal, V Marquina, Francisco Raga Baixauli

Bibliographic record

VenueRevista Española de Cirugía Ortopédica y Traumatología · 2024
Typearticle
Languagees
FieldMedicine
TopicHip and Femur Fractures
Canadian institutionsnot available
Fundersnot available
KeywordsIntramedullary rodMedicineBlood lossIntertrochanteric fractureSurgeryRandomized controlled trialNail (fastener)Hip fractureOsteoporosisInternal medicineFemur

Abstract

fetched live from OpenAlex

Objective: To compare short versus long intramedullary nails for intertrochanteric hip fractures in terms of efficacy and safety. Methods: We included cohort studies and randomized clinical trials. The methodological quality of the studies was assessed by the Newcastle–Ottawa Scale. The meta-analysis was performed using the Review Manager 5.4. Heterogeneity was checked with the I2 test. A fixed effects model was adopted if there was no heterogeneity. Results: Twelve studies were included. The reoperations rate was lower in the short nail group (OR 0.58, 95% CI 0.38–0.88) and there were no differences regarding the peri-implant fracture rate (OR 1.77, 95% CI 0.68–4.60). Surgery time and blood loss was significantly higher in the long nail group (MD −12.44, 95% CI −14.60 to (−10.28)) (MD −19.36, 95% CI −27.24 to (−11.48)). There were no differences in functional outcomes. Conclusions: The long nail showed a higher reoperation rate, blood loss and surgery time compared to the short nail. Objetivo: Comparar el clavo intramedular corto frente al clavo largo en las fracturas intertrocantéricas de cadera en términos de eficacia y de seguridad. Métodos: Se incluyeron estudios de cohortes y ensayos clínicos aleatorizados. La calidad metodológica de los estudios se evaluó mediante la escala Newcastle-Ottawa. El metaanálisis se realizó mediante el Review Manager 5.4. La heterogeneidad se comprobó con la prueba I2. Se adoptó un modelo de efectos fijos si no existía heterogeneidad. Resultados: Se incluyeron doce estudios. La tasa de reoperaciones fue inferior en el grupo de clavo corto (OR: 0,58; IC 95%: 0,38-0,88) y no existieron diferencias en cuanto a la tasa de fractura peri-implante (OR: 1,77; IC 95%: 0,68-4,60). El tiempo de cirugía y la pérdida de sangre fueron significativamente mayores en el grupo de clavo largo (DM: −12,44; IC 95%: −14,60 a −10,28) (DM: −19,36; IC 95%: −27,24 a −11,48). No existieron diferencias respecto a los resultados funcionales. Conclusiones: El clavo largo mostró una mayor tasa de reoperación, pérdida de sangre y tiempo quirúrgico en comparación con el clavo corto.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.009
metaresearch head score (Gemma)0.042
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.046
Threshold uncertainty score0.152

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0090.042
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0040.006
Bibliometrics0.0070.007
Science and technology studies0.0010.001
Scholarly communication0.0040.002
Open science0.0020.002
Research integrity0.0030.002
Insufficient payload (model declined to judge)0.0460.005

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.323
Teacher spread0.309 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueRevista Española de Cirugía Ortopédica y TraumatologíaSame topicHip and Femur FracturesFrench-language works237,207