Abstract

fetched live from OpenAlex

Background: The introduction of highly cross-linked polyethylene (HXLPE) acetabular liners has greatly improved the wear performance of metal-on-PE bearing surfaces used in total hip arthroplasty. Changing the sterilization environment and adding thermal treatments, such as remelting or annealing, were introduced to limit on-shelf and in vivo oxidation of cross-linked liners. This study compares the wear properties of the remelted A-CLASS (MicroPort) HXLPE liner to a sequentially annealed HXLPE. Methods: This retrospective study assessed linear and volumetric wear rates using Martell Hip Analysis Suite, and clinical performance through incidences of revision surgeries. A total of 80 remelted and 53 annealed liners were included in the wear analysis. All hips were reviewed for revisions. Results: There were no significant differences in steady-state linear or volumetric wear rates for remelted and annealed liners, 0.01 (u00010.07 to 0.14) vs u00010.01 (u00010.11 to 0.1) mm/y (p=0.28) and u00011.03 (u000130.99 to 45.43) vs u00011.31 (u000132.23 to 23.70) mm3/y (p=0.30), respectively. Both cohorts were below the 0.1 mm/yr linear wear threshold. The wear rates for patients with femoral head sizes 36 mm were not significantly different than those with 32 and 28 mm femoral head sizes (p=0.60). Similarly, wear rates for patients with an excessively vertical acetabular component (>50u0014) were not significantly different than those with standard acetabular component orientations (p=0.97). No hips were revised due to liner-related complications. Conclusion: The wear rates of the A-CLASS remelted HXLPE acetabular liner wear rates were comparableto those of a sequentially annealed HXLPE. Further long-term studies are required to ensure acceptable resistance to fatigue and in vivo oxidation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.036
GPT teacher head0.308
Teacher spread0.271 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2019
Admission routes1
Has abstractyes

Explore more

Same topicRecycling and Waste Management TechniquesFrench-language works237,207