MétaCan
Menu
Back to cohort
Record W4391618447 · doi:10.1088/1361-6560/ad2713

Voxel-wise dose rate calculation in clinical pencil beam scanning proton therapy

2024· article· en· W4391618447 on OpenAlexaff
Juliane Daartz, Thomas M. Madden, Arthur Lalonde, E Cascio, Joost Verburg, Helen A. Shih, Shannon M. MacDonald, Rachael L. Hachadorian, Jan Schuemann

Bibliographic record

VenuePhysics in Medicine and Biology · 2024
Typearticle
Languageen
FieldMedicine
TopicRadiation Therapy and Dosimetry
Canadian institutionsCentre Hospitalier de l’Université de Montréal
FundersNational Cancer InstituteNational Institutes of Health
KeywordsProton therapyPencil-beam scanningProtonVoxelPencil (optics)Nuclear medicineBeam (structure)Dose rateRelative biological effectivenessMedical physicsPhysicsMedicineOpticsIrradiationRadiologyNuclear physics

Abstract

fetched live from OpenAlex

Abstract Objective . Clinical outcomes after proton therapy have shown some variability that is not fully understood. Different approaches have been suggested to explain the biological outcome, but none has yet provided a comprehensive and satisfactory rationale for observed toxicities. The relatively recent transition from passive scattering (PS) to pencil beam scanning (PBS) treatments has significantly increased the voxel-wise dose rate in proton therapy. In addition, the dose rate distribution is no longer uniform along the cross section of the target but rather highly heterogeneous, following the spot placement. We suggest investigating dose rate as potential contributor to a more complex proton RBE model. Approach . Due to the time structure of the PBS beam delivery the instantaneous dose rate is highly variable voxel by voxel. Several possible parameters to represent voxel-wise dose rate for a given clinical PBS treatment plan are detailed. These quantities were implemented in the scripting environment of our treatment planning system, and computations experimentally verified. Sample applications to treated patient plans are shown. Main results . Computed dose rates we experimentally confirmed. Dose rate maps vary depending on which method is used to represent them. Mainly, the underlying time and dose intervals chosen determine the topography of the resultant distributions. The maximum dose rates experienced by any target voxel in a given PBS treatment plan in our system range from ∼100 to ∼450 Gy(RBE)/min, a factor of 10–100 increase compared to PS. These dose rate distributions are very heterogeneous, with distinct hot spots. Significance . Voxel-wise dose rates for current clinical PBS treatment plans vary greatly from clinically established practice with PS. The exploration of different dose rate measures to evaluate potential correlations with observed clinical outcomes is suggested, potentially adding a missing component in the understanding of proton relative biological effectiveness (RBE).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.405
Threshold uncertainty score0.312

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.291
GPT teacher head0.483
Teacher spread0.193 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2024
Admission routes1
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicRadiation Therapy and DosimetryFrench-language works237,207