First direct <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mmultiscripts><mml:mi>Be</mml:mi><mml:mprescripts/><mml:none/><mml:mn>7</mml:mn></mml:mmultiscripts></mml:math> electron-capture <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mi>Q</mml:mi></mml:math>-value measurement toward high-precision searches for neutrino physics beyond the Standard Model
Bibliographic record
Abstract
We report the first direct measurement of the nuclear electron-capture (EC) decay $Q$ value of $^{7}\mathrm{Be}\ensuremath{\rightarrow}^{7}\mathrm{Li}$ via high-precision Penning trap mass spectrometry (PTMS). This was performed using the LEBIT Penning trap located at the National Superconducting Cyclotron Laboratory/Facility for Rare Isotope Beams (NSCL/FRIB) using the newly commissioned Batch-Mode Ion-Source (BMIS) to deliver the unstable $^{7}\mathrm{Be}^{+}$ samples. With a measured value of ${Q}_{EC}=861.963(23)$ keV, this result is three times more precise than any previous determination of this quantity. This improved precision and accuracy of the $^{7}\mathrm{Be}$ EC decay $Q$ value is critical for ongoing experiments that measure the recoiling nucleus in this system as a signature to search for beyond the Standard Model (BSM) neutrino physics using $^{7}\mathrm{Be}$-doped superconducting sensors. This experiment has extended LEBIT capabilities, using the first low-energy beam delivered by BMIS at FRIB for PTMS, as well as measuring the lightest-mass isotopes so far with LEBIT.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.004 | 0.001 |
| Meta-epidemiology (narrow) | 0.002 | 0.003 |
| Meta-epidemiology (broad) | 0.002 | 0.005 |
| Bibliometrics | 0.000 | 0.002 |
| Science and technology studies | 0.003 | 0.002 |
| Scholarly communication | 0.003 | 0.003 |
| Open science | 0.005 | 0.004 |
| Research integrity | 0.002 | 0.005 |
| Insufficient payload (model declined to judge) | 0.001 | 0.003 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; both teacher heads agree on what is shown here.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".