MétaCan
Menu
Back to cohort
Record W4391970312 · doi:10.1186/s12954-024-00963-6

Feeling safer: effectiveness, feasibility, and acceptability of continuous pulse oximetry for people who smoke opioids at overdose prevention services in British Columbia, Canada

2024· article· en· W4391970312 on OpenAlexafffundabout
Jessica Moe, Tamara Chavez, Charotte Marr, Fred Cameron, Damian Feldman-Kiss, Yueqiao Elle Wang, Jessica Xavier, Zahra Mamdani, Roy Purssell, Amy Salmon, Jane A. Buxton

Bibliographic record

VenueHarm Reduction Journal · 2024
Typearticle
Languageen
FieldEngineering
TopicNon-Invasive Vital Sign Monitoring
Canadian institutionsSt. Paul's HospitalCentre for Advancing Health OutcomesVancouver Native Health SocietyStornoway Diamond (Canada)BC Centre for Disease ControlUniversity of British Columbia
FundersCanadian Institutes of Health Research
KeywordsMedicineHarm reductionOpioid overdoseHeroinThematic analysisMedical emergencyPulse oximetryPublic health(+)-NaloxoneNursingPsychiatryOpioidQualitative researchDrug

Abstract

fetched live from OpenAlex

BACKGROUND: Smoking is the most common mode of unregulated opioid consumption overall and implicated in fatal overdoses in British Columbia (BC). In part, perception of decreased risk (e.g., fewer who smoke carry naloxone kits) and limited smoking-specific harm reduction services contribute to overdose deaths. Overdose prevention services (OPS) offer supervised settings for drug use. Continuous pulse oximetry, common in acute care, allows real-time, remote oxygen monitoring. We evaluated the effectiveness of a novel continuous pulse oximetry protocol aimed at allowing physical distancing (as required by COVID-19, secluded spaces, and to avoid staff exposure to vaporized opioids), its feasibility, and acceptability at OPS for people who smoke opioids. METHODS: This was a mixed methods survey study. We developed a continuous pulse oximetry protocol in collaboration with clinical experts and people with lived/living experience of substance use. We implemented our protocol from March to August 2021 at four OPS in BC permitting smoking. We included adults (≥ 18 years) presenting to OPS to smoke opioids. Peer researchers collected demographic, health, and substance use information, and conducted structured observations. OPS clients participating in our study, OPS staff, and peer researchers completed post-monitoring surveys. We analyzed responses using a thematic inductive approach and validated themes with peer researchers. RESULTS: We included 599 smoking events. OPS clients participating in our study had a mean age of 38.5 years; 73% were male. Most (98%) reported using "down", heroin, or fentanyl; 48% concurrently used other substances (32% of whom reported stimulants); 76% reported smoking alone in the last 3 days; and 36% reported an overdose while smoking. Respondents reported that the protocol facilitated physical distancing, was easy to use, high satisfaction, improved confidence, improved sense of safety, and that they would use it again. CONCLUSIONS: Continuous pulse oximetry allowed safe physical distancing, was feasible, and acceptable in monitoring people who smoke opioids at OPS.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.165
Threshold uncertainty score0.808

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.246
Teacher spread0.236 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2024
Admission routes3
Has abstractyes

Explore more

Same venueHarm Reduction JournalSame topicNon-Invasive Vital Sign MonitoringFrench-language works237,207