MétaCan
Menu
Back to cohort
Record W4391986107 · doi:10.1051/ject/2024003

Designing an experimental method for assessing biocompatibility of circuit coatings using biomarkers for platelet activation during cardiopulmonary bypass

2024· article· en· W4391986107 on OpenAlexaff
Meghal Sancheti, Mitchell Rentschler, Charlotte Bolch, Weidang Li, Katelyn Necco, Thomas Rath, Mitra Esfandiarei, Nathaniel Darban

Bibliographic record

VenueJournal of ExtraCorporeal Technology · 2024
Typearticle
Languageen
FieldMedicine
TopicCardiac and Coronary Surgery Techniques
Canadian institutionsUniversity of British Columbia
FundersMidwestern University
KeywordsCardiopulmonary bypassBiocompatibilityPlateletPlatelet activationBiomedical engineeringMaterials scienceMedicineCardiologyInternal medicineMetallurgy

Abstract

fetched live from OpenAlex

INTRODUCTION: Cardiopulmonary bypass is an essential component of cardiothoracic surgeries. However, significant complications such as systemic inflammatory response syndrome (SIRS) resulting from cardiopulmonary bypass (CPB) are a common occurrence due to contact between circulating blood and foreign surfaces that leads to platelet activation. It is suggested that different available CPB circuit coatings can potentially reduce platelet activation. However, there have been no published evidence-based reports confirming these claims. In addition, there is no well-established protocol for studying platelet activation biomarkers during CPB in vitro in a laboratory setting. METHODS: Surface by Terumo. Fresh bovine blood samples were collected and circulated through the CPB circuit following the standard protocol used in the operation rooms. Blood samples were then collected at 5 min, 30 min, and 55 min during the circulation. Blood plasmas were separated and subjected to enzyme-linked immunosorbent assay to measure most established platelet activation markers P-selectin, Platelet Factor 4 (PF4), Glycoprotein IIb/IIIa (GPIIb/IIIa), and β-thromboglobulin (β-TG) at different time points. RESULTS: The biomarker values at 30 min and 55 min were compared to the base values at 5 min for each type of CPB circuit. The results of the means from all measured biomarkers showed data measurements that indicated no significant variability within each coating. All collected data points fell within ±2 SD of the means, which was considered acceptable variations across technical replicates. Conclusion: In this study, we were able to establish an in vitro protocol in the laboratory setting that is precise and reliable with minimum intra-variability. This established protocol will allow for future studies in which different coated CPB circuits can be compared for their effectiveness in blocking platelet activation during the CPB.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.149
Threshold uncertainty score0.738

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.054
GPT teacher head0.373
Teacher spread0.319 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueJournal of ExtraCorporeal TechnologySame topicCardiac and Coronary Surgery TechniquesFrench-language works237,207