MétaCan
Menu
Back to cohort
Record W4392195009 · doi:10.1002/jez.2799

Ultrasound images of the ascending aorta of anesthetized northern fur seals and Steller sea lions confirm that the aortic bulb maintains continuous blood flow

2024· article· en· W4392195009 on OpenAlexafffund
Rhea L. Storlund, David A. S. Rosen, Martin Haulena, Shubhayan Sanatani, Jessica Vander Zaag, Andrew W. Trites

Bibliographic record

VenueJournal of Experimental Zoology Part A Ecological and Integrative Physiology · 2024
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicCongenital heart defects research
Canadian institutionsVancouver AquariumUniversity of British ColumbiaBC Children's HospitalFisheries and Oceans Canada
FundersNatural Sciences and Engineering Research Council of CanadaBC Children's Hospital
KeywordsAscending aortaStroke volumeAortaCardiac cycleCardiologyDiastoleInternal medicineBlood flowAnatomyBulbMedicineHeart rateBiologyBlood pressureEcology

Abstract

fetched live from OpenAlex

The increased size and enhanced compliance of the aortic bulb-the enlargement of the ascending aorta-are believed to maintain blood flow in pinnipeds during extended periods of diastole induced by diving bradycardia. The aortic bulb has been described ex vivo in several species of pinnipeds, but in vivo measurements are needed to investigate the relationship between structure and function. We obtained ultrasound images using electrocardiogram-gated transesophageal echocardiography during anesthesia and after atropine administration to assess the relationship between aortic bulb anatomy and cardiac function (heart rate, stroke volume, cardiac output) in northern fur seals (Callorhinus ursinus) and Steller sea lions (Eumetopias jubatus). We observed that the aortic bulb in northern fur seals and Steller sea lions expands during systole and recoils over the entire diastolic period indicating that blood flow is maintained throughout the entire cardiac cycle as expected. The stroke volumes we measured in the fur seals and sea lions fit the values predicted based on body size in mammals and did not change with increased heart rates, suggesting that greater stroke volumes are not needed for aortic bulb function. Overall, our results suggest that peripheral vasoconstriction during diving is sufficient to modulate the volume of blood in the aortic bulb to ensure that flow lasts over the entire diastolic period. These results indicate that the shift of blood into the aortic bulb of pinnipeds is a fundamental mechanism caused by vasoconstriction while diving, highlighting the importance of this unique anatomical adaptation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.094
Threshold uncertainty score0.590

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.002
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.290
Teacher spread0.275 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Experimental Zoology Part A Ecological and Integrative PhysiologySame topicCongenital heart defects researchFrench-language works237,207