A Compact Relativistic Magnetron With Diffraction Output of TE₁₁ Mode
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
A compact configuration of relativistic magnetron with DO (MDO) is proposed in order to output the TE11 mode. In this diffraction output (DO) configuration, a plate-inserted coaxial TEM-TE11 converter is introduced to obtain a TE11 radiation pattern through full cavity extraction. Meanwhile, the DO adopts a ridge circular waveguide to reduce its radial size. To match the plate-inserted coaxial TEM-TE11 converter, the resonator system uses an eight-cavity slow wave structure and selects <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\pi$ </tex-math></inline-formula>-mode fundamental harmonic as the operating mode. Through particle-in-cell (PIC) simulations, the proposed MDO of TE11 mode can generate an RF power of 1.1 GW with a pure TE11 mode at the frequency of 2.88 GHz when the diode voltage is 400 kV and the working magnetic field is 0.47 T, and the device efficiency is 61%.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it