MétaCan
Menu
Back to cohort
Record W4392469259 · doi:10.1177/19476035231226418

Comparison of Clinical Efficacy and Mechanical Characteristics of Two Knee Distraction Devices With Relevance for Clinical Practice

2024· article· en· W4392469259 on OpenAlexfundaboutno aff
T. Struik, Mylène P. Jansen, R.G.P. Lafeber, F.P. Lafeber, S.C. Mastbergen

Bibliographic record

VenueCartilage · 2024
Typearticle
Languageen
FieldMedicine
TopicBone fractures and treatments
Canadian institutionsnot available
FundersUniversitair Medisch Centrum UtrechtUniversiteit UtrechtZonMwArthritis SocietyDutch Arthritis Society
KeywordsDistractionMedicineOsteoarthritisWOMACStiffnessRadiographyAdverse effectClinical efficacyOrthodonticsSurgeryInternal medicine

Abstract

fetched live from OpenAlex

OBJECTIVE: Distraction treatment for severe osteoarthritis below the age of 65 successfully postpones arthroplasty. Most patients have been treated with a general external fixator or a device specifically intended for knee distraction. This study compares clinical efficacy of both devices in retrospect and their mechanical characteristics. DESIGN: Clinical efficacy 2 years posttreatment was compared using retrospective data from patients with severe knee osteoarthritis treated with knee distraction; 63 with the Dynamic Monotube (Stryker GmbH, Switzerland) and 65 with the KneeReviver (ArthroSave BV, the Netherlands). Changes in Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain, stiffness, and function, general well-being (SF-36), cartilage thickness by radiographic joint space widening, and adverse events during treatment were assessed. Axial stiffness of clinically feasible configurations was assessed by bench testing for the Dynamic Monotube triax system and the KneeReviver. RESULTS: No differences were observed in clinical efficacy, nor in mechanical characteristics and adverse events between the two devices. Although with large variation, both showed a clinically relevant improvement. In mechanical testing, contact between articular surfaces was observed for both devices at physiological loading. Stiffness of applied configurations strongly varied and primarily depended on bone pin length. CONCLUSIONS: Patients treated with a general intended-use device or a distraction-specific device both experienced clinical and structural efficacy although with significant variation between patients. The latter may be the result of varying mechanical characteristics resulting from differences in clinical configurations of the devices and actual loading. The exact role of full/partial mechanical unloading of the joint during distraction treatment remains unclear.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.408
Threshold uncertainty score0.352

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.090
GPT teacher head0.485
Teacher spread0.395 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueCartilageSame topicBone fractures and treatmentsFrench-language works237,207