MétaCan
Menu
Back to cohort
Record W4392500056 · doi:10.1021/acsami.3c16336

X-ray-Sensitive Doped CaF<sub>2</sub>-Based MRI Contrast Agents for Local Radiation Dose Measurement

2024· article· en· W4392500056 on OpenAlexafffund
Adriaan L. Frencken, Devon Richtsmeier, Russell L. Leonard, Aleia G. Williams, C. E. Johnson, Jacqueline A. Johnson, Barbara Błasiak, A. Orlef, Agnieszka Skorupa, Maria Sokół, Bogusław Tomanek, Wayne Beckham, Magdalena Bazalova‐Carter, Frank C. J. M. van Veggel

Bibliographic record

VenueACS Applied Materials & Interfaces · 2024
Typearticle
Languageen
FieldMaterials Science
TopicLanthanide and Transition Metal Complexes
Canadian institutionsRoyal Jubilee HospitalUniversity of AlbertaUniversity of CalgaryUniversity of Victoria
FundersBritish Columbia Knowledge Development FundNatural Sciences and Engineering Research Council of CanadaCanada Research ChairsNarodowe Centrum NaukiCanada Foundation for Innovation
KeywordsIonizing radiationMaterials scienceX-rayRadiationProtonMagnetic resonance imagingMedical imagingRadiation therapyDopingNuclear magnetic resonanceIrradiationNuclear medicineRadiochemistryRadiologyOptoelectronicsOpticsChemistryMedicinePhysics

Abstract

fetched live from OpenAlex

Ionizing radiation has become widely used in medicine, with application in diagnostic techniques, such as computed tomography (CT) and radiation therapy (RT), where X-rays are used to diagnose and treat tumors. The X-rays used in CT and, in particular, in RT can have harmful side effects; hence, an accurate determination of the delivered radiation dose is of utmost importance to minimize any damage to healthy tissues. For this, medical specialists mostly rely on theoretical predictions of the delivered dose or external measurements of the dose. To extend the practical use of ionizing radiation-based medical techniques, such as magnetic resonance imaging (MRI)-guided RT, a more precise measurement of the internal radiation dose internally is required. In this work, a novel approach is presented to measure dose in liquids for potential future in vivo applications. The strategy relies on MRI contrast agents (CAs) that provide a dose-sensitive signal. The demonstrated materials are (citrate-capped) CaF 2 nanoparticles (NPs) doped with Eu 3+ or Fe 2+ /Fe 3+ ions. Free electrons generated by ionizing radiation allow the reduction of Eu 3+, which produces a very small contrast in MRI, to Eu 2+, which induces a strong contrast. Oxidative species generated by high-energy X-rays can be measured indirectly using Fe 2+ because it oxidizes to Fe 3+, increasing the contrast in MRI. Notably, in the results, a strong increase in the proton relaxation rates is observed for the Eu 3+ -doped NPs at 40 kV. At 6 MV, a significant increase in proton relaxation rates is observed using CaF 2 NPs doped with Fe 2+ /Fe 3+ after irradiation. The presented concept shows great promise for use in the clinic to measure in vivo local ionizing radiation dose, as these CAs can be intravenously injected in a saline solution.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.036
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.027
GPT teacher head0.255
Teacher spread0.227 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueACS Applied Materials & InterfacesSame topicLanthanide and Transition Metal ComplexesFrench-language works237,207