MétaCan
Menu
Back to cohort
Record W4392627612 · doi:10.5194/egusphere-egu24-6316

Evaluation of analytical techniques for organic peroxide measurements in polar and non-polar systems.

2024· preprint· en· W4392627612 on OpenAlexaff
Daniel Alba-Elena, Xinke Wang, Jonathan P. D. Abbatt, Edelmira Valero, M. T. Baeza‐Romero

Bibliographic record

Venuenot available
Typepreprint
Languageen
FieldEnvironmental Science
TopicWater Quality Monitoring and Analysis
Canadian institutionsUniversity of Toronto
Fundersnot available
KeywordsChemistryRadicalIodometryOzonolysisAqueous solutionPeroxideSolventAbsorbanceAutoxidationHydrogen peroxidePhotochemistryOzoneAqueous two-phase systemChemical polarityPrimary (astronomy)PolarOrganic chemistryChromatographyMolecule

Abstract

fetched live from OpenAlex

Peroxides and hydroperoxides are generated during the oxidation of volatile organic compounds (VOCs) in both gaseous and aqueous phases. The ozonolysis of alkenes in the gas phase is a significant source of peroxy radicals (RO2) in both nocturnal and diurnal chemistry. In the absence of NO, the recombination reactions of RO2 radicals lead to the formation of H2O2 and/or organic hydroperoxides (Atkinson, 2000). Hydroperoxides are highly reactive and play a crucial role in atmospheric chemistry, such as the oxidation of SO2 to H2SO4 in atmospheric aqueous droplets and heterogeneous SO2 uptake (Wang, 2021). Moreover, peroxides are suggested to constitute a significant fraction of laboratory-generated secondary organic aerosol (SOA) (Docherty 2005) and can serve as reservoirs of HOx and ROx radicals (Li, 2016).Various spectrophotometric methods have been employed to quantify SOA-bound peroxides offline. The Iodometry method quantifies peroxides present in any form (H2O2, ROOH, and ROOR) except for tertiary dialkyl peroxides. The principle of the method is A faster and more sensitive alternative to this method was developed by our group, which accelerates the reaction by microwave heating (Alba-Elena, 2023). These assays typically use water as a solvent. Here, for the first time, an alternative procedure using 1-propanol as an organic solvent is proposed and tested for H2O2 and various less reactive peroxides.Other spectrophotometric methods include: the 4-nitrophenyl boronic acid (NPBA) assay, which is based on the reaction between the hydroperoxide and NPBA to form the colored nitrophenol, the absorbance of which is measured (Jiang, 2017), and the Fenton reaction-assisted ferrous-xylenol (FOX2) assay, which is based on the oxidation of Fe2+ by the organic hydroperoxide to form Fe3+, which forms a complex with Xylenol orange that can be detected spectrometrically (Morrison, 2023).All these assays, as well as the 2,7-dichlorofluorescein-based horseradish peroxidase (DCF-HRP) assay, a widely used fluorescence method that is more sensitive to H2O2 compared to other organic peroxides and hydroperoxides (Badali, 2015), have been tested using water and polar organic solvents such as 1-propanol and non-polar organic solvents such as chloroform. Their response to different types of peroxide: H2O2, tertbutyl hydroperoxide, ditertbutyl peroxide, methyl ethyl ketone peroxide, and dibenzoyl peroxide, has been evaluated. A comparative study of the results, their different characteristics, and their possible interferences has been conducted. ACKNOWLEDGEMENTThis research was supported by the Spanish Ministry of Science, Innovation and Universities (MICINN, https://www.ciencia.gob.es/) with grants PID2019-106468RB-I00 and PID2022-139724OB-I00, funded by MCIN/AEI/10.13039/501100011033 and co-funded by the European Union; the UCLM groups research grant No. 2022-GRIN-34199, funded by the own research plan of the UCLM for applied research projects, co-financed by the European Fund for Regional Development (FEDER). D. Alba thanks MCIN/AEI for his “Contrato Predoctoral” Ref BES-2020-094874 associated to the project indicated.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.012
metaresearch head score (Gemma)0.016
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.012
Threshold uncertainty score0.065

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0120.016
Meta-epidemiology (narrow)0.0030.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0030.002
Science and technology studies0.0010.002
Scholarly communication0.0020.002
Open science0.0020.003
Research integrity0.0030.003
Insufficient payload (model declined to judge)0.0040.004

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.086
GPT teacher head0.338
Teacher spread0.252 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2024
Admission routes1
Has abstractyes

Explore more

Same topicWater Quality Monitoring and AnalysisFrench-language works237,207