A comparison of multichannel singlet oxygen luminescence dosimetry (MSOLD) and singlet oxygen explicit dosimetry (SOED)
Bibliographic record
Abstract
Direct detection of singlet-state oxygen ([<sup>1</sup>O<sub>2</sub>]) is a crucial objective in type II photodynamic therapy (PDT), achievable through the implementation of multispectral singlet oxygen dosimetry (MSOLD). To accurately assess the amount of reactive singlet oxygen, the Singlet Oxygen Explicit Dosimetry (SOED) model was developed, incorporating parameters such as light fluence rate, photosensitizer concentration, and ground-state oxygen concentration. This study focuses on comparing the results obtained from MSOLD and SOED by measuring the singlet oxygen signal via a commercial InGaAs spectrometer and subsequently calculating reactive singlet oxygen based on the SOED theory. A continuous-wave laser emitting at 630nm is employed to excite Protoporphyrin IX (PPIX) in methanol, varying the concentration from 10mg/kg to 100mg/kg. Utilizing the Singular Value Decomposition (SVD) algorithm, the measured singlet oxygen spectrum is fitted to extract the singlet oxygen signal. To simulate clinical PDT scenarios, real-time singlet oxygen spectra are collected over 1200 seconds, employing a 1.5mm diameter optic fiber for signal collection. Ground-state oxygen concentration is measured using a commercial oxygen probe while the laser is inactive, and photosensitizer concentration is assessed via a custom-made contact probe. Additionally, the fluence rate of the laser is measured using an isotropic detector. The Reactive Singlet Oxygen is then calculated using the SOED model, incorporating the photosensitizer concentration, oxygen concentration, and photon fluence rate. Detailed comparisons between MSOLD and SOED results are presented, offering valuable insights into the accuracy and reliability of both methods in quantifying singlet-state oxygen during PDT.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".