MétaCan
Menu
Back to cohort
Record W4392755538 · doi:10.1186/s12890-024-02932-y

The total-breath method yields higher values of DLCO and TLC than the conventional method

2024· article· en· W4392755538 on OpenAlexaff
Rudolf A. Jörres, Christian Buess, Andreas Piecyk, Bruce Thompson, Sanja Stanojevic, H Magnussen

Bibliographic record

VenueBMC Pulmonary Medicine · 2024
Typearticle
Languageen
FieldMedicine
TopicChronic Obstructive Pulmonary Disease (COPD) Research
Canadian institutionsDalhousie University
Fundersnot available
KeywordsDLCOMedicinePlethysmographCOPDMean differenceSpirometerSignificant differenceNuclear medicineLung functionInternal medicineDiffusing capacityLungConfidence interval

Abstract

fetched live from OpenAlex

Abstract Background The 2017 ATS/ERS technical standard for measuring the single-breath diffusing capacity (DLCO) proposed the “rapid-gas-analyzer” (RGA) or, equivalently, “total-breath” (TB) method for the determination of total lung capacity (TLC). In this study, we compared DLCO and TLC values estimated using the TB and conventional method, and how estimated TLC using these two methods compared to that determined by body plethysmography. Method A total of 95 people with COPD (GOLD grades 1–4) and 23 healthy subjects were studied using the EasyOne Pro (ndd Medical Technologies, Switzerland) and Master Screen Body (Vyaire Medical, Höchberg, Germany). Results On average the TB method resulted in higher values of DLCO (mean ± SD Δ = 0.469 ± 0.267; 95%CI: 0.420; 0.517 mmol*min-1*kPa-1) and TLC (Δ = 0.495 ± 0.371; 95%CI: 0.427; 0.562 L) compared with the conventional method. In healthy subjects the ratio between TB and conventional DLCO was close to one. TLC estimated using both methods was lower than that determined by plethysmography. The difference was smaller for the TB method (Δ = 1.064 ± 0.740; 95%CI: 0.929; 1.199 L) compared with the conventional method (Δ = 1.558 ± 0.940; 95%CI: 1.387; 1.739 L). TLC from body plethysmography could be estimated as a function of TB TLC and FEV 1 Z-Score with an accuracy (normalized root mean square difference) of 9.1%. Conclusion The total-breath method yielded higher values of DLCO and TLC than the conventional analysis, especially in subjects with COPD. TLC from the total-breath method can also be used to estimate plethysmographic TLC with better accuracy than the conventional method. The study is registered under clinicaltrial.gov NCT04531293.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.799
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.038
GPT teacher head0.369
Teacher spread0.331 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueBMC Pulmonary MedicineSame topicChronic Obstructive Pulmonary Disease (COPD) ResearchFrench-language works237,207