MétaCan
Menu
Back to cohort
Record W4392757469 · doi:10.1101/2024.03.07.24303787

Artificial intelligence-generated smart impression from 9.8-million radiology reports as training datasets from multiple sites and imaging modalities

2024· preprint· en· W4392757469 on OpenAlexaff
Parisa Kaviani, Mannudeep K. Kalra, Subba R. Digumarthy, Karen J. Rodriguez, Sheela Agarwal, Rupert Brooks, Sovann En, Tarik K. Alkasab, Bernardo C. Bizzo, Keith J. Dreyer

Bibliographic record

VenuemedRxiv · 2024
Typepreprint
Languageen
FieldMedicine
TopicRadiology practices and education
Canadian institutionsNuance Communications (Canada)
Fundersnot available
KeywordsImpressionMedicineRadiologyMedical physicsPearson product-moment correlation coefficientRDFModalitiesCorrelationProtocol (science)Computer scienceArtificial intelligenceStatisticsMathematicsWorld Wide WebPathology

Abstract

fetched live from OpenAlex

Abstract Importance Automatic generation of the impression section of radiology report can help make radiologists efficient and avoid reporting errors. Objective To evaluate the relationship, content, and accuracy of an Powerscribe Smart Impression (PSI) against the radiologists’ reported findings and impression (RDF). Design, Setting, and Participants The institutional review board approved retrospective study developed and trained an PSI algorithm (Nuance Communications, Inc.) with 9.8 million radiology reports from multiple sites to generate PSI based on information including the protocol name and the radiologists-dictated findings section of radiology reports. Three radiologists assessed 3879 radiology reports of multiple imaging modalities from 8 US imaging sites. For each report, we assessed if PSI can accurately reproduce the RDF in terms of the number of clinically significant findings and radiologists’ style of reporting while avoiding potential mismatch (with the findings section in terms of size, location, or laterality). Separately we recorded the word count for PSI and RDF. Data were analyzed with Pearson correlation and paired t-tests. Main Outcomes and Measures The data were ground truthed by three radiologists. Each radiologists recorded the frequency of the incidental/significant findings, any inconsistency between the RDF and PSI as well as the stylistic evaluation overall evaluation of PSI. Area under the curve (AUC), correlation coefficient, and the percentages were calculated. Results PSI reports were deemed either perfect (91.9%) or acceptable (7.68%) for stylistic concurrence with RDF. Both PSI (mismatched Haller’s Index) and RDF (mismatched nodule size) had one mismatch each. There was no difference between the word counts of PSI (mean 33±23 words/impression) and RDF (mean 35±24 words/impression) (p>0.1). Overall, there was an excellent correlation (r= 0.85) between PSI and RDF for the evolution of findings (negative vs. stable vs. new or increasing vs. resolved or decreasing findings). The PSI outputs (2%) requiring major changes pertained to reports with multiple impression items. Conclusion and Relevance In clinical settings of radiology exam interpretation, the Powerscribe Smart Impression assessed in our study can save interpretation time; a comprehensive findings section results in the best PSI output.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.023
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.032

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.023
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.087
GPT teacher head0.349
Teacher spread0.262 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2024
Admission routes1
Has abstractyes

Explore more

Same venuemedRxivSame topicRadiology practices and educationFrench-language works237,207