The use of lung ultrasound in evaluation of extravascular lung water in hemodialysis patients: Systematic review and meta‐analysis

2024· review· en· W4392772521 on OpenAlexvenueno aff
Anas Elgenidy, Mostafa Atef Amin, Ahmed K. Awad, Abdullah Emad, Abdelrahman Nassar, Omar Alomarı, Radwa Ibrahim, Faeq Husain‐Syed, Mostafa Aly

Bibliographic record

VenueHemodialysis International · 2024
Typereview
Languageen
FieldMedicine
TopicUltrasound in Clinical Applications
Canadian institutionsnot available
Fundersnot available
KeywordsHemodialysisMedicineInferior vena cavaLungIntravascular volume statusUltrasoundBlood pressureInternal medicineCardiologySurgeryRadiology

Abstract

fetched live from OpenAlex

RATIONALE AND OBJECTIVES: Determining dry weight is crucial for optimizing hemodialysis, influencing efficacy, cardiovascular outcomes, and overall survival. Traditional clinical assessment methods for dry weight, relying on factors such as blood pressure and edema, frequently lack reliability. Lung ultrasound stands out as a promising tool for assessing volume status, given its non-invasiveness and reproducibility. This study aims to explore the role of Lung ultrasound in evaluating the impact of hemodialysis and ultrafiltration on extravascular lung water, with a specific focus on changes in B-lines post-hemodialysis compared to pre-hemodialysis. MATERIALS AND METHODS: The research encompassed searches across PubMed, WOS, and Scopus databases for studies related to lung ultrasound and hemodialysis. A meta-analysis was then performed to determine the mean differences in various parameters before compared to after, hemodialysis, including the number of B-lines, indexed end-inspiratory and end-expiratory inferior vena cava diameters, inferior vena cava collapsibility index, weight, blood pressure, and serum levels of NT-pro-BNP. RESULTS: Our meta-analysis, included 33 studies with 2301 hemodialysis patients, revealed a significant decrease in the number of B-lines post-hemodialysis (mean difference = 8.30, 95% CI [3.55 to 13.05]). Furthermore, there was a noteworthy reduction in inspiratory and expiratory inferior vena cava diameters post-hemodialysis (mean difference = 2.32, 95% CI [0.31 to 4.33]; mean difference = 4.05, 95% CI [2.44 to 5.65], respectively). Additionally, a significant positive correlation was observed between B-lines and the maximum inferior vena cava diameter both pre- and post-hemodialysis (correlation coefficient = 0.39; correlation coefficient = 0.32, respectively). CONCLUSION: These findings indicate the effectiveness of lung ultrasound in detection of volume overload and assessment of response to ultrafiltration in hemodialysis patients.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.005
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.558
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0060.005
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0070.004
Bibliometrics0.0010.002
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.125
GPT teacher head0.412
Teacher spread0.287 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueHemodialysis InternationalSame topicUltrasound in Clinical ApplicationsFrench-language works237,207