Improving Breath Detection From Pulsed-Flow Oxygen Sources Using a New Nasal Interface

2024· article· en· W4392948473 on OpenAlexafffund
Cole Christianson, Efrem Violato, Mozhgan Sabz, Hossein Rouhani, Thomas Waring, Andrew R. Martin

Bibliographic record

VenueRespiratory Care · 2024
Typearticle
Languageen
FieldMedicine
TopicRespiratory Support and Mechanisms
Canadian institutionsNorthern Alberta Institute of TechnologyUniversity of Alberta
FundersMitacs
KeywordsNasal cannulaMedicineBreathingCannulaAnesthesiaOxygen therapyOxygenBiomedical engineeringSurgery

Abstract

fetched live from OpenAlex

BACKGROUND: Patients with COPD and other lung diseases are treated with long-term oxygen therapy (LTOT). Portable oxygen sources are required to administer LTOT while maintaining patient autonomy. Existing portable oxygen equipment has limitations that can hinder patient mobility. A novel nasal interface is presented in this study, aiming to enhance breath detection and triggering efficiency of portable pulsed-flow oxygen devices, thereby improving patient mobility and independence. METHOD: To examine the effectiveness of the new interface, 8 respiratory therapists participated in trials using different oxygen sources (tank with oxygen-conserving device, SimplyGo Mini portable oxygen concentrator [POC], and OxyGo NEXT POC) and breathing types (nasal and oral) while using either the new nasal interface or a standard cannula. Each trial was video recorded so participant breaths could be retroactively matched with a pulse/no-pulse response, and triggering success rates were calculated by dividing the number of oxygen pulses by the number of breaths in each trial. After each trial, volunteers were asked to rate their perceived breathing resistance. RESULTS: Nasal breathing consistently resulted in higher triggering success rates compared to oral breathing for pulsed-flow oxygen devices. POCs exhibited higher triggering success rates than did the oxygen tanks with conserving device. However, there were no significant differences in triggering success rates between the two POC models. The new nasal interface demonstrated improved triggering success rates compared to the standard cannula. Whereas the new nasal interface was associated with a slight increase in perceived breathing resistance during nasal breathing trials, participants reported manageable resistance levels when using the interface. CONCLUSIONS: This study demonstrates that the new nasal interface can improve triggering success rates of pulsed-flow oxygen devices during both nasal and oral breathing scenarios. Further research involving patient trials is recommended to understand the clinical implications of improved pulse triggering.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.256
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.288
Teacher spread0.264 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueRespiratory CareSame topicRespiratory Support and MechanismsFrench-language works237,207