MétaCan
Menu
Back to cohort
Record W4393321239 · doi:10.1016/j.artd.2024.101361

Techniques and Technologies for the Intraoperative Assessment of Component Positioning, Leg Lengths, and Offset in Total Hip Arthroplasty: A Systematic Review

2024· review· en· W4393321239 on OpenAlexaff
Cedric Chung, Ibrahim Bin Hazzaa, Raja Hakim, Michael G. Zywiel

Bibliographic record

VenueArthroplasty Today · 2024
Typereview
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsPublic Health OntarioUniversity of TorontoUniversity Health Network
Fundersnot available
KeywordsMedicineTotal hip arthroplastyArthroplastySurgery

Abstract

fetched live from OpenAlex

Background: Many techniques and technologies exist for the intraoperative assessment of component positioning, leg lengths, and offset in total hip arthroplasty, but with limited comparative data. We conducted a systematic review of the available literature to evaluate the range of techniques and technologies for the intraoperative assessment of component position as well as leg lengths and offset in terms of accuracy, precision, surgical time, cost, and relationship to clinical outcomes. Methods: A comprehensive search of the Embase and Medline databases from 1974 to 2023 was performed. We included controlled or comparative prospective clinical studies. Cochrane's risk-of-bias tool for randomized trials and Risk of Bias in Non-Randomized Studies - of Interventions tools were used by 2 independent reviewers to evaluate each study for risk of bias. We conducted both qualitative and quantitative analyses of the studies included. However, a meta-analysis was deemed not to be feasible due to heterogeneity. Results: Our review included 25 studies with 52 intraoperative techniques and technologies. Mechanical guides and computerized navigation were most frequently evaluated in the included studies. Computerized navigation systems consistently showed the greatest accuracy and precision across all measures, at the cost of longer mean operative time. In contrast, freehand techniques demonstrated the poorest accuracy and precision. Insufficient data were found to reach any meaningful conclusions in terms of differences in overall surgical cost or clinical outcomes. Conclusions: Evidence shows that computerized navigation systems are most accurate and precise in positioning components during total hip arthroplasty. Further research is needed to determine their health and economic impact and whether the accuracy and precision of navigated techniques are justified in terms of clinical outcomes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: Systematic review
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.361
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0030.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.023
GPT teacher head0.341
Teacher spread0.318 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueArthroplasty TodaySame topicOrthopaedic implants and arthroplastyFrench-language works237,207