MétaCan
Menu
Back to cohort
Record W4393943208 · doi:10.1016/j.jcjo.2024.03.007

Apical dose versus volume dose of Ruthenium-106 brachytherapy for uveal melanoma

2024· article· en· W4393943208 on OpenAlexvenueno aff
Jeremy P.M. Flanagan, Lotte S. Fog, Melvin A. Astrahan, Lachie J. Talbot, D McKay, Claire Phillips, John D. McKenzie, Roderick O’Day

Bibliographic record

VenueCanadian Journal of Ophthalmology · 2024
Typearticle
Languageen
FieldMedicine
TopicOcular Oncology and Treatments
Canadian institutionsnot available
Fundersnot available
KeywordsBrachytherapyApex (geometry)Nuclear medicineMedicineMelanomaRadiation therapyRadiologyCancer researchAnatomy

Abstract

fetched live from OpenAlex

Objective Ruthenium-106 brachytherapy is commonly used to treat uveal melanomas. Most centres prescribe a radiation dose to the tumour apex that is calculated with the tumour located in the centre of the plaque. Recent work suggests that D 99% —the minimum radiation dose delivered to 99% of tumour volume—may be a better predictor of tumour control than apex dose. Both dosing regimens may be affected by tumour and treatment variables differently. We explored the effect of differences in these variables on volume and apex dose using a 3-dimensional planning model. Methods The time required to deliver 100 Gy to the tumour apices of representative tumours ranging from 2- to 6-mm thickness with central plaque positioning was calculated in Plaque Simulator™. This treatment time was used for further calculations, including D 99% with central plaque placement, and apical and tumour volume doses when tumour and plaque characteristics were altered, including eccentric plaque placement, either away from (tilt) or along (offset) scleral surface, tumour shape, and plaque type. Results D 99% was always greater than the apex dose when plaques were placed centrally, and the difference increased with tumour thickness. Increasing degrees of tumour offset reduced apical dose and D 99% , with a greater effect on apical dose for thicker and D 99% for thinner tumours, respectively. Differences in tumour shape and plaque type had idiosyncratic effects on apical and volume dosing. Conclusion D 99% and apex dose are affected by tumour and treatment characteristics in different ways, highlighting the complexity of radiation delivery to uveal tumours.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.037
GPT teacher head0.332
Teacher spread0.295 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueCanadian Journal of OphthalmologySame topicOcular Oncology and TreatmentsFrench-language works237,207