Telemedicine With Wearable Technologies in Patients Undergoing Hematopoietic Cell Transplantation and Chimeric Antigen Receptor T-Cell Therapy (TEL-HEMATO Study): Prospective Noninterventional Single-Center Study
Bibliographic record
Abstract
BACKGROUND: Patients with hematological malignancies receiving hematopoietic cell transplantation (HCT) or chimeric antigen receptor (CAR) T-cell therapy are at risk of developing serious clinical complications after discharge. OBJECTIVE: The aim of the TEL-HEMATO study was to improve our telehealth platform for the follow-up of patients undergoing HCT or CAR T-cell therapy during the first 3 months after discharge with the addition of wearable devices. METHODS: Eleven patients who received autologous (n=2) or allogeneic (n=5) HCT or CAR T-cell therapy (n=4) for hematological malignancies were screened from November 2022 to July 2023. Two patients discontinued the study after enrollment. The telehealth platform consisted of the daily collection of vital signs, physical symptoms, and quality of life assessment up to 3 months after hospital discharge. Each patient received a clinically validated smartwatch (ScanWatch) and a digital thermometer, and a dedicated smartphone app was used to collect these data. Daily revision of the data was performed through a web-based platform by a hematologist or a nurse specialized in HCT and CAR T-cell therapy. RESULTS: Vital signs measured through ScanWatch were successfully collected with medium/high adherence: heart rate was recorded in 8/9 (89%) patients, oxygen saturation and daily steps were recorded in 9/9 (100%) patients, and sleeping hours were recorded in 7/9 (78%) patients. However, temperature recorded manually by the patients was associated with lower compliance, which was recorded in 5/9 (55%) patients. Overall, 5/9 (55%) patients reported clinical symptoms in the app. Quality of life assessment was completed by 8/9 (89%) patients at study enrollment, which decreased to 3/9 (33%) at the end of the third month. Usability was considered acceptable through ratings provided on the System Usability Scale. However, technological issues were reported by the patients. CONCLUSIONS: While the addition of wearable devices to a telehealth clinical platform could have potentially synergic benefits for HCT and CAR T-cell therapy patient monitoring, noncomplete automation of the platform and the absence of a dedicated telemedicine team still represent major limitations to be overcome. This is especially true in our real-life setting where the target population generally comprises patients of older age with a low digital education level.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.002 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.001 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.001 | 0.000 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.000 | 0.001 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.002 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".