MétaCan
Menu
Back to cohort
Record W4393999111 · doi:10.1097/md.0000000000037697

Efficacy of cementless porous tantalum tibial components versus cemented tibial components in primary total knee arthroplasty: A meta-analysis

2024· review· en· W4393999111 on OpenAlexaboutno aff
Lei Li, Chao Pan, Xingyan Zhang, Wei Liu, Tingting Zhang, Yu‐Fan Liu, Jingyi Li, Yuhang Ma, Chenfan Jia, Xinying Liu, Chunbao Shi

Bibliographic record

VenueMedicine · 2024
Typereview
Languageen
FieldMedicine
TopicTotal Knee Arthroplasty Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineTotal knee arthroplastyOsteoarthritisMeta-analysisCochrane LibraryArthroplastyConfidence intervalTantalumImplantRadiological weaponKnee JointSurgeryDentistryInternal medicineMaterials science

Abstract

fetched live from OpenAlex

BACKGROUND: Total knee arthroplasty involves the use of cemented tibial components for fixation. In recent years, cementless porous tantalum tibial components have been increasingly utilized. The aim of this meta-analysis was to compare the efficacy of cementless porous tantalum tibial components with traditional cemented tibial components in terms of postoperative outcomes following total knee arthroplasty. METHODS: Relevant literature was retrieved from Cochrane Library, PubMed, Embase, and Web of Science using the search terms "(trabecular metal OR Porous tantalum)" AND "knee" up to July 2023. The weighted mean difference with a 95% confidence interval was used as the effect size measure to evaluate the functional recovery of the knee joint, radiological analysis, complications, and implant revisions between cementless porous tantalum tibial components and traditional cemented tibial components after total knee arthroplasty. Review Manager 5.3 was utilized to conduct a comparative analysis of all included studies. RESULTS: Nine studies with a total of 1117 patients were included in this meta-analysis, consisting of 447 patients in the porous tantalum group and 670 patients in the cemented group. Radiological analysis demonstrated that the porous tantalum group had better outcomes than the cemented group (P < .05). The combined results for the 5-year and 10-year follow-ups, range of motion, Western Ontario and McMaster University Osteoarthritis Index, complications, and implant revisions showed no significant differences between the porous tantalum and cemented groups. CONCLUSION: The results of the 5-year and 10-year follow-ups indicate that the use of cementless porous tantalum tibial components is comparable to traditional cemented tibial components, with no significant advantages observed. However, at the 5-year follow-up, the porous tantalum group demonstrated a good bone density in the proximal tibia. Future studies with a larger sample size, long-term clinical follow-up, and radiological results are needed to verify the differences between the 2 implants.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.013
metaresearch head score (Gemma)0.021
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: Meta-analysis
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.016
Threshold uncertainty score0.069

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0130.021
Meta-epidemiology (narrow)0.0030.002
Meta-epidemiology (broad)0.0160.060
Bibliometrics0.0050.004
Science and technology studies0.0010.001
Scholarly communication0.0040.002
Open science0.0020.001
Research integrity0.0030.002
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.139
GPT teacher head0.358
Teacher spread0.219 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueMedicineSame topicTotal Knee Arthroplasty OutcomesFrench-language works237,207