MétaCan
Menu
Back to cohort
Record W4393999317 · doi:10.1053/j.gastro.2024.03.039

Rapid Endoscopic Diagnosis of Benign Ulcerative Colorectal Diseases With an Artificial Intelligence Contextual Framework

2024· article· en· W4393999317 on OpenAlexfundno aff
Xiaobei Luo, Jiahao Wang, Chuanchuan Tan, Qi Dou, Zelong Han, Zhenjiang Wang, Farah Tasnim, Xiyu Wang, Qiang Zhan, Xiang Li, Qunyan Zhou, Jianbin Cheng, Fabiao Liao, Hon Chi Yip, Jiayi Jiang, Robby T. Tan, Side Liu, Hanry Yu

Bibliographic record

VenueGastroenterology · 2024
Typearticle
Languageen
FieldMedicine
TopicColorectal Cancer Screening and Detection
Canadian institutionsnot available
FundersBasic and Applied Basic Research Foundation of Guangdong ProvinceInvestment Agriculture FoundationScience and Technology Planning Project of Guangdong ProvinceBiomedical Research CouncilMechanobiology Institute, SingaporeMinistry of Education, IndiaAgency for Science, Technology and ResearchMinistry of Education of the People's Republic of ChinaNational Natural Science Foundation of China
KeywordsMedicineUlcerative colitisGastroenterologyInternal medicineDisease

Abstract

fetched live from OpenAlex

BACKGROUND & AIMS: Benign ulcerative colorectal diseases (UCDs) such as ulcerative colitis, Crohn's disease, ischemic colitis, and intestinal tuberculosis share similar phenotypes with different etiologies and treatment strategies. To accurately diagnose closely related diseases like UCDs, we hypothesize that contextual learning is critical in enhancing the ability of the artificial intelligence models to differentiate the subtle differences in lesions amidst the vastly divergent spatial contexts. METHODS: White-light colonoscopy datasets of patients with confirmed UCDs and healthy controls were retrospectively collected. We developed a Multiclass Contextual Classification (MCC) model that can differentiate among the mentioned UCDs and healthy controls by incorporating the tissue object contexts surrounding the individual lesion region in a scene and spatial information from other endoscopic frames (video-level) into a unified framework. Internal and external datasets were used to validate the model's performance. RESULTS: Training datasets included 762 patients, and the internal and external testing cohorts included 257 patients and 293 patients, respectively. Our MCC model provided a rapid reference diagnosis on internal test sets with a high averaged area under the receiver operating characteristic curve (image-level: 0.950 and video-level: 0.973) and balanced accuracy (image-level: 76.1% and video-level: 80.8%), which was superior to junior endoscopists (accuracy: 71.8%, P < .0001) and similar to experts (accuracy: 79.7%, P = .732). The MCC model achieved an area under the receiver operating characteristic curve of 0.988 and balanced accuracy of 85.8% using external testing datasets. CONCLUSIONS: These results enable this model to fit in the routine endoscopic workflow, and the contextual framework to be adopted for diagnosing other closely related diseases.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.012
Threshold uncertainty score0.024

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.023
GPT teacher head0.291
Teacher spread0.267 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2024
Admission routes1
Has abstractno

Explore more

Same venueGastroenterologySame topicColorectal Cancer Screening and DetectionFrench-language works237,207