MétaCan
Menu
Back to cohort
Record W4394846125 · doi:10.11613/bm.2024.020705

CLSI-based verification and de novo establishment of reference intervals for common biochemical assays in Croatian newborns

2024· article· en· W4394846125 on OpenAlexaboutno aff
Jasminka Stipanović-Kastelić, Mirjana Mariana Kardum Paro, Andrea Radeljak, Sonja Perkov, Iva Friščić

Bibliographic record

VenueBiochemia Medica · 2024
Typearticle
Languageen
FieldMedicine
TopicClinical Laboratory Practices and Quality Control
Canadian institutionsnot available
Fundersnot available
KeywordsCroatianReference valuesMedicineBilirubinInternal medicine

Abstract

fetched live from OpenAlex

Graphical abstract Highlights • Referent persons were selected using the direct a posteriori sampling method • Nineteen most commonly used biochemical assays on Beckman Coulter AU680 • Harmonized reference intervals are suitable for most assays • De novo reference intervals for potassium, magnesium and direct bilirubin were determined IntroductionThis study aimed to examine whether the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) reference intervals for 19 commonly used biochemical assays (potassium, sodium, chloride, calcium, magnesium, inorganic phosphorous, glucose, urea, creatinine, direct and total bilirubin, C-reactive protein (CRP), total protein, albumin, aspartate aminotransferase (AST), alanine aminotransferase (ALT), gamma-glutamyl transferase (GGT), alkaline phosphatase (ALP) and lactate dehydrogenase (LD)) could be applied to the newborn population of one Croatian clinical hospital. Materials and methodsReference interval verification was performed according to the CLSI EP28-A3c guidelines. Samples of healthy newborns were selected using the direct a posteriori sampling method and analyzed on the Beckman Coulter AU680 biochemical analyzer. If verification wasn’t satisfactory, further procedure included de novo determination of own reference intervals by analyzing 120 samples of healthy newborns. ResultsAfter the first set of measurements, 14/19 tested reference intervals were adopted for use: calcium, inorganic phosphorous, glucose, urea, creatinine, total bilirubin, CRP, total protein, albumin, AST, ALT, GGT, ALP and LD. A second set of samples was tested for 5 analytes: potassium, sodium, chloride, magnesium and direct bilirubin. The verification results of the additional samples for sodium and chloride were satisfactory, while the results for potassium, magnesium and direct bilirubin remained unsatisfactory and new reference intervals were determined. ConclusionsThe CALIPER reference intervals can be implemented into routine laboratory and clinical practice for the tested newborn population for most of the analyzed assays, while own reference intervals for potassium, magnesium and direct bilirubin have been determined.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.032
metaresearch head score (Gemma)0.027
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.036
Threshold uncertainty score0.168

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0320.027
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0050.003
Science and technology studies0.0010.001
Scholarly communication0.0020.000
Open science0.0030.002
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.059
GPT teacher head0.395
Teacher spread0.337 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueBiochemia MedicaSame topicClinical Laboratory Practices and Quality ControlFrench-language works237,207