MétaCan
Menu
Back to cohort
Record W4394880659 · doi:10.1002/htj.23063

Experimental and parametric analysis of a novel hybrid thermal management strategy for cylindrical lithium‐ion cells

2024· article· en· W4394880659 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueHeat Transfer · 2024
Typearticle
Languageen
FieldEngineering
TopicAdvanced Battery Technologies Research
Canadian institutionsOntario Tech University
Fundersnot available
KeywordsAirflowMaterials scienceDuct (anatomy)Reynolds numberPressure dropCoolantThermalPhase-change materialParametric statisticsComputational fluid dynamicsMechanicsMechanical engineeringThermodynamicsEngineeringMathematicsPhysics

Abstract

fetched live from OpenAlex

Abstract This paper reports on a novel hybrid thermal management strategy. It uses secondary coolants (air and liquid) to withdraw heat simultaneously from the composite phase change material, resulting in increased heat extraction capability of the composite phase change material and improved thermal environment of the battery module. The significance of this strategy is that the fluid used in the liquid cooling stays stationary. Comprehensive experimental and numerical studies are performed, and parametric studies are conducted to reduce the volume of the phase change material, size of the air duct, and airflow Reynolds number. The numerical results showed that the maximum temperature was limited to 27.8°C, and a high‐temperature uniformity of 0.4°C was obtained. Furthermore, the required volume of the composite phase change material is reduced by ~50%. Additionally, beyond a 6 mm height of the air duct, the reduction in maximum pressure drop is not significant enough, and it is considered the optimal height, and a Reynolds number of 1950 is considered the optimal airflow Reynolds number. Therefore, the proposed thermal management concept for the battery module can sustain the thermal environment needed for the effective operation of Lithium‐ion batteries.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.325
Threshold uncertainty score0.460

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.033
GPT teacher head0.297
Teacher spread0.264 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it