MétaCan
Menu
Back to cohort
Record W4394972114 · doi:10.1021/acs.analchem.3c04988

SCALiR: A Web Application for Automating Absolute Quantification of Mass Spectrometry-Based Metabolomics Data

2024· article· en· W4394972114 on OpenAlexafffund
Luis F. Ponce, Stephanie L. Bishop, Sören Wacker, Ryan A. Groves, Ian A. Lewis

Bibliographic record

VenueAnalytical Chemistry · 2024
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicMetabolomics and Mass Spectrometry Studies
Canadian institutionsUniversity of Calgary
FundersNational Institute of Allergy and Infectious DiseasesNatural Sciences and Engineering Research Council of CanadaAlberta InnovatesCanada Foundation for InnovationGovernment of CanadaAlberta Innovates - Health SolutionsThermo Fisher ScientificCanadian Institutes of Health ResearchGenome Canada
KeywordsChemistryMetabolomicsMass spectrometryChromatographyAnalytical Chemistry (journal)

Abstract

fetched live from OpenAlex

Quantitative liquid chromatography–mass spectrometry (LC-MS)-based metabolomics is becoming an important approach for studying complex biological systems but presents several technical challenges that limit its widespread use. Computing metabolite concentrations using standard curves generated from standard mixtures of known concentrations is a labor-intensive process that is often performed manually. Currently, there are few options for open-source software tools that can automatically calculate metabolite concentrations. Herein, we introduce SCALiR (standard curve application for determining linear ranges), a new web-based software tool specifically built for this task, which allows users to automatically transform LC-MS signals into absolute quantitative data ( https://www.lewisresearchgroup.org/software ). SCALiR uses an algorithm that automatically finds the equation of the line of best fit for each standard curve and uses this equation to calculate compound concentrations from the LC-MS signal. Using a standard mix containing 77 metabolites, we show a close correlation between the concentrations calculated by SCALiR and the expected concentrations of each compound ( R 2 = 0.99 for a y = x curve fitting). Moreover, we demonstrate that SCALiR reproducibly calculates concentrations of midrange standards across ten analytical batches (average coefficient of variation 0.091). SCALiR can be used to calculate metabolite concentrations either using external calibration curves or by using internal standards to correct for matrix effects. This open-source and vendor agnostic software offers users several advantages in that (1) it requires only 10 s of analysis time to compute concentrations of >75 compounds, (2) it facilitates automation of quantitative workflows, and (3) it performs deterministic evaluations of compound quantification limits. SCALiR therefore provides the metabolomics community with a simple and rapid tool that enables rigorous and reproducible quantitative metabolomics studies.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: Not applicable
GenreCandidate signal: Software · Consensus signal: Software
Teacher disagreement score0.034
Threshold uncertainty score0.113

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.006
Meta-epidemiology (narrow)0.0030.001
Meta-epidemiology (broad)0.0020.002
Bibliometrics0.0040.001
Science and technology studies0.0010.001
Scholarly communication0.0020.002
Open science0.0030.003
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0340.028

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.029
GPT teacher head0.313
Teacher spread0.284 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreSoftware

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicMetabolomics and Mass Spectrometry StudiesFrench-language works237,207