MétaCan
Menu
Back to cohort
Record W4395046411 · doi:10.24908/pocus.v9i1.16795

Point of Care Ultrasound for Diagnosis and Management in Heart Failure: A Targeted Literature Review

2024· article· en· W4395046411 on OpenAlexvenueno aff
Sabina Yampolsky, Alan C. Kwan, Susan Cheng, Ilan Kedan

Bibliographic record

VenuePOCUS Journal · 2024
Typearticle
Languageen
FieldMedicine
TopicUltrasound in Clinical Applications
Canadian institutionsnot available
Fundersnot available
KeywordsMedicinePoint of care ultrasoundDiureticHeart failureUltrasoundCardiologyInternal medicineIntensive care medicineRadiology

Abstract

fetched live from OpenAlex

BACKGROUND: Cardiac point of care ultrasound (POCUS) has shown increasing utility as a tool for diagnosing and managing heart failure (HF). Within cardiology, intravascular volume assessment leveraging visualization of the inferior vena cava (IVC) is a central aspect of care, as IVC size correlates with central venous pressure. This targeted literature review aimed to examine the existing literature assessing the use of POCUS in diagnosis and management of HF patients utilizing POCUS-based IVC measurement either alone or in combination with secondary methods. METHODS: A targeted PubMed and Ovid database search up until August 28, 2023 using a keyword search was completed. Studies that did not include IVC assessment with POCUS in HF were excluded. RESULTS: The initial search using both PubMed and Ovid resulted in 370 journal publications. After exclusion criteria were used 15 studies were included in the review. Studies were grouped into three categories: 1) how well POCUS was able to identify HF, 2) whether POCUS-based findings correlated with other measures evaluating HF and was able to predict the effect of diuretic administration, and 3) whether POCUS-based findings served as a good prognostic indicator. The 5 studies that evaluated HF identification with POCUS found that both diagnostic sensitivity and specificity may reach 90%-100% when IVC measurement was coupled with a lung ultrasound assessing the presence of B-lines or pleural effusion. Five studies assessing POCUS findings correlating with other HF measures and diuretic effect found that IVC diameter changed significantly with diuretic administration (p<0.05). All 6 studies assessing POCUS as a predictor of long-term mortality or hospital readmission found measures that achieved statistical significance with p<0.05. CONCLUSIONS: Including POCUS as standard-of-care - both as a diagnostic tool in the emergency department and a management tool in in-patient and out-patient facilities - may improve the treatment of HF.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.021
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.017
Threshold uncertainty score0.022

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.021
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0040.003
Bibliometrics0.0170.014
Science and technology studies0.0010.001
Scholarly communication0.0020.002
Open science0.0020.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0060.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.351
Teacher spread0.331 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2024
Admission routes1
Has abstractyes

Explore more

Same venuePOCUS JournalSame topicUltrasound in Clinical ApplicationsFrench-language works237,207