Mid-Term Outcomes of a Short Modular Neck-Preserving Cementless Hip Stem: A Retrospective Study With a 6-Year Minimum Follow-Up
Bibliographic record
Abstract
Background: The neck-preserving cementless short stem represents a valid therapeutic option for total hip replacement in high-functional-demand patients, but few studies are available about the use of modularity in the last-generation short stem. The aim of the study was to evaluate the mid-term survival of a specific implant design that combines partial collum short hip stem with neck modularity; assessing the functional status was the second endpoint. Methods: A retrospective single-center cohort study was conducted on 75 patients aged 35 to 80 years, with a minimum 6-year follow-up. Patients with neurological/rheumatic pathologies and previous hip surgeries were excluded. All the patients underwent total hip replacement with a short modular neck-preserving cementless hip stem. Clinical outcomes, complications, revisions, and the Western Ontario and McMaster Universities Osteoarthritis Index, Harris hip score, and Short Form 12-Item Health Survey (SF-12) questionnaires were evaluated. The results were compared with healthy population's data extracted from the literature, stratified by age. Results: The Kaplan-Meier analysis revealed a 10-year implant survival rate of 96.7%, coupled with a revision rate of 1.3%. Results showed a Harris hip score and physical SF-12 significantly lower and a mental SF-12 higher when compared to healthy population. No statistically significant differences emerged when comparing groups based on neck modularity. Conclusions: The short modular neck-preserving cementless hip stem emerged as a reasonable choice for patients with elevated functional demands, ensuring good clinical outcomes while preserving bone integrity. The use of a modular neck in short stems didn't show any mechanical problems in the mid-term.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".