MétaCan
Menu
Back to cohort
Record W4396568996 · doi:10.2196/54983

Designing a Smartphone-Based Pulse Oximeter for Children in South Africa (Phefumla Project): Qualitative Analysis of Human-Centered Design Workshops With Health Care Workers

2024· article· en· W4396568996 on OpenAlexvenueno aff
E.I. Ilhan, Lucia N Jola, Marieke M. van der Zalm, Mike Bernstein, Pierre Goussard, Andrew Redfern, Anneke C. Hesseling, Graeme Hoddinott, Eric D. McCollum, Carina King

Bibliographic record

VenueJMIR Human Factors · 2024
Typearticle
Languageen
FieldMedicine
TopicGlobal Health and Surgery
Canadian institutionsnot available
FundersEuropean and Developing Countries Clinical Trials PartnershipFogarty International Center
KeywordsQualitative analysisHealth carePulse (music)Qualitative researchMedical educationMedicinePsychologyComputer scienceSociologyTelecommunicationsPolitical scienceSocial science

Abstract

fetched live from OpenAlex

Background: Pulse oximeters noninvasively measure blood oxygen levels, but these devices have rarely been designed for low-resource settings and are inconsistently available at outpatient clinics. Objective: The Phefumla project aims to develop and validate a pediatric smartphone-based pulse oximeter designed specifically for this context. We present the process of human-centered oximeter design with health care workers in South Africa. Methods: We purposively sampled 19 health care workers from 5 clinics in Khayelitsha, Cape Town. Using a human-centered design approach, we conducted participatory workshops with four activities with health care workers: (1) they received 3D-printed prototypes of potential oximeter designs to provide feedback; (2) we demonstrated on dolls how they would use the novel oximeter; (3) they used pile sorting to rank design features and suggest additional features they desired; and (4) they designed their preferred user interface using a whiteboard, marker, and magnetized features that could be repositioned. We audio recorded the workshops, photographed outputs, and took detailed field notes. Analysis involved iterative review of these data to describe preferences, identify key design updates, and provide modifications. Results: Participants expressed a positive sentiment toward the idea of a smartphone pulse oximeter and suggested that a pediatric device would address an important gap in outpatient care. Specifically, participants expressed a preference for the prototype that they felt enabled more diversity in the way it could be used. There was a strong tendency to prioritize pragmatic design features, such as robustness, which was largely dictated by health care worker context. They also added features that would allow the oximeter device to serve other clinical functions in addition to oxygen saturation measurement, such as temperature and respiratory rate measurements. Conclusions: Our end user-centered rapid participatory approach led to tangible design changes and prompted design discussions that the team had not previously considered. Overall, health care workers prioritized pragmatism for pediatric pulse oximeter device design.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.368
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0020.002
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.094
GPT teacher head0.405
Teacher spread0.311 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueJMIR Human FactorsSame topicGlobal Health and SurgeryFrench-language works237,207