MétaCan
Menu
Back to cohort
Record W4396686841 · doi:10.1002/mp.17117

Rapid multi‐catheter segmentation for magnetic resonance image‐guided catheter‐based interventions

2024· article· en· W4396686841 on OpenAlexaff
Amanda M. Aleong, Alejandro Berlín, Jette Borg, Joelle Helou, Akbar Beiki‐Ardakani, Alexandra Rink, Srinivas Raman, Peter Chung, Robert Weersink

Bibliographic record

VenueMedical Physics · 2024
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsPrincess Margaret Cancer CentreUniversity of Toronto
Fundersnot available
KeywordsCatheterMagnetic resonance imagingSegmentationRadiologyMedicineComputer scienceComputer visionArtificial intelligence

Abstract

fetched live from OpenAlex

BACKGROUND: Magnetic resonance imaging (MRI) is the gold standard for delineating cancerous lesions in soft tissue. Catheter-based interventions require the accurate placement of multiple long, flexible catheters at the target site. The manual segmentation of catheters in MR images is a challenging and time-consuming task. There is a need for automated catheter segmentation to improve the efficiency of MR-guided procedures. PURPOSE: To develop and assess a machine learning algorithm for the detection of multiple catheters in magnetic resonance images used during catheter-based interventions. METHODS: In this work, a 3D U-Net was trained to retrospectively segment catheters in scans acquired during clinical MR-guided high dose rate (HDR) prostate brachytherapy cases. To assess confidence in segmentation, multiple AI models were trained. On clinical test cases, average segmentation results were used to plan the brachytherapy delivery. Dosimetric parameters were compared to the original clinical plan. Data was obtained from 35 patients who underwent HDR prostate brachytherapy for focal disease with a total of 214 image volumes. 185 image volumes from 30 patients were used for training using a five-fold cross validation split to divide the data for training and validation. To generate confidence measures of segmentation accuracy, five trained models were generated. The remaining five patients (29 volumes) were used to test the performance of the trained model by comparison to manual segmentations of three independent observers and assessment of dosimetric impact on the final clinical brachytherapy plans. RESULTS: The network successfully identified 95% of catheters in the test set at a rate of 0.89 s per volume. The multi-model method identified the small number of cases where AI segmentation of individual catheters was poor, flagging the need for user input. AI-based segmentation performed as well as segmentations by independent observers. Plan dosimetry using AI-segmented catheters was comparable to the original plan. CONCLUSION: The vast majority of catheters were accurately identified by AI segmentation, with minimal impact on plan outcomes. The use of multiple AI models provided confidence in the segmentation accuracy and identified catheter segmentations that required further manual assessment. Real-time AI catheter segmentation can be used during MR-guided insertions to assess deflections and for rapid planning of prostate brachytherapy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.005
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.029
GPT teacher head0.352
Teacher spread0.323 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207