MétaCan
Menu
Back to cohort
Record W4396709288 · doi:10.1016/j.mri.2024.05.004

Denoising of the gradient artifact present in simultaneous studies of muscle blood oxygen level dependent (BOLD) signal and electromyography (EMG)

2024· article· en· W4396709288 on OpenAlexafffund
Alejandro Amador‐Tejada, Joshua E. McGillivray, Dinesh Kumbhare, Michael D. Noseworthy

Bibliographic record

VenueMagnetic Resonance Imaging · 2024
Typearticle
Languageen
FieldEngineering
TopicMuscle activation and electromyography studies
Canadian institutionsUniversity of TorontoMcMaster UniversitySt. Joseph’s Healthcare Hamilton
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsArtifact (error)SubtractionElectromyographyComputer scienceNoise reductionSIGNAL (programming language)ScannerArtificial intelligenceNoise (video)Pattern recognition (psychology)Biomedical engineeringComputer visionMathematicsMedicineImage (mathematics)Physical medicine and rehabilitation

Abstract

fetched live from OpenAlex

The MR-induced gradient artifact affects EMG recordings during simultaneous muscle BOLD/EMG acquisitions. However, no dedicated hardware can remove the gradient artifact easily, and alternative methods are expensive and time-consuming. This study aimed to develop three denoising methods requiring different processing levels and MR-compatible hardware. At two time points, surface EMG was recorded from the lower leg of 6 participants (50:50 sex ratio, age = 26.24.6 yrs., height = 173.59.2 cm, weight = 71.511.4 kg) using a plantar flexion-based block design consisting of 30s of rest followed by 30s of flexion for 5 min, under three conditions: inside the MRI bore, with and without a BOLD sequence (3 T, BOLD sequence, GRE EPI, 10 slices, 64×64 matrix, 2 mm thickness, and TE/TR/flip = 35/3000 ms/70), and outside the MRI environment. Simultaneous BOLD/EMG recordings were denoised using average artifact subtraction with three methods of artifact template creation, each having varying timing and hardware requirements. Method M1 builds the artifact template by recording the scanner triggers coming from the MRI; M2 creates the artifact template with a constant artifact period computed as TR/[number of slices]; M3 estimates the artifact template by looking at the periodicity of the gradient artifact located in the EMG recordings. Following postprocessing, SNR analysis was performed, comparing rest-to-flexion periods, to assess the efficacy of denoising methods and to compare differences between conditions. Linear mixed-effects models showed no significant differences in the mean SNR between denoising methods (p = 0.656). Furthermore, EMG SNR measurements were significantly affected by the magnetic environment (p < 0.05) but not by muscle fatigue over time (p = 0.975). EMG recordings contaminated with gradient artifacts during simultaneous BOLD/EMG can be efficiently denoised using all proposed methods, with two methods requiring no extra hardware. With minimal post-processing, EMG can easily be performed during muscle BOLD MRI studies.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.771
Threshold uncertainty score0.641

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.232
Teacher spread0.218 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueMagnetic Resonance ImagingSame topicMuscle activation and electromyography studiesFrench-language works237,207