MétaCan
Menu
Back to cohort
Record W4396734407 · doi:10.1186/s40635-024-00631-w

Dynamic changes of hepatic vein Doppler velocities predict preload responsiveness in mechanically ventilated critically ill patients

2024· article· en· W4396734407 on OpenAlexaff
Mario Bruna, Sebastián Alfaro, Felipe Muñoz, Liliana Cisternas, Cecilia Gonzalez, Rodrigo Conlledo, Rodrigo Ulloa-Morrison, Marcos Huilcamán, Jaime Retamal, Ricardo Castro, Philippe Rola, Adrian Wong, Eduardo R. Argaiz, Roberto Contreras, Glenn Hernández, Eduardo Kattan

Bibliographic record

VenueIntensive Care Medicine Experimental · 2024
Typearticle
Languageen
FieldMedicine
TopicHemodynamic Monitoring and Therapy
Canadian institutionsCentres Intégré Universitaires de Santé et de Services Sociaux
FundersAgencia Nacional de Investigación y Desarrollo
KeywordsPreloadMedicineUltrasoundCardiologyMechanical ventilationDoppler effectHemodynamicsInternal medicineRadiology

Abstract

fetched live from OpenAlex

BACKGROUND: Assessment of dynamic parameters to guide fluid administration is one of the mainstays of current resuscitation strategies. Each test has its own limitations, but passive leg raising (PLR) has emerged as one of the most versatile preload responsiveness tests. However, it requires real-time cardiac output (CO) measurement either through advanced monitoring devices, which are not routinely available, or echocardiography, which is not always feasible. Analysis of the hepatic vein Doppler waveform change, a simpler ultrasound-based assessment, during a dynamic test such as PLR could be useful in predicting preload responsiveness. The objective of this study was to assess the diagnostic accuracy of hepatic vein Doppler S and D-wave velocities during PLR as a predictor of preload responsiveness. METHODS: Prospective observational study conducted in two medical-surgical ICUs in Chile. Patients in circulatory failure and connected to controlled mechanical ventilation were included from August to December 2023. A baseline ultrasound assessment of cardiac function was performed. Then, simultaneously, ultrasound measurements of hepatic vein Doppler S and D waves and cardiac output by continuous pulse contour analysis device were performed during a PLR maneuver. RESULTS: Thirty-seven patients were analyzed. 63% of the patients were preload responsive defined by a 10% increase in CO after passive leg raising. A 20% increase in the maximum S wave velocity after PLR showed the best diagnostic accuracy with a sensitivity of 69.6% (49.1-84.4) and specificity of 92.8 (68.5-99.6) to detect preload responsiveness, with an area under curve of receiving operator characteristic (AUC-ROC) of 0.82 ± 0.07 (p = 0.001 vs. AUC-ROC of 0.5). D-wave velocities showed worse diagnostic accuracy. CONCLUSIONS: Hepatic vein Doppler assessment emerges as a novel complementary technique with adequate predictive capacity to identify preload responsiveness in patients in mechanical ventilation and circulatory failure. This technique could become valuable in scenarios of basic hemodynamic monitoring and when echocardiography is not feasible. Future studies should confirm these results.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.273
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.319
Teacher spread0.306 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueIntensive Care Medicine ExperimentalSame topicHemodynamic Monitoring and TherapyFrench-language works237,207