MétaCan
Menu
Back to cohort
Record W4396814155 · doi:10.52198/24.sti.44.os1789

Low Rate of Early Periprosthetic Fractures in Direct Anterior Total Hip Arthroplasty with a Triple-Tapered Wedge Stem

2024· article· en· W4396814155 on OpenAlexaboutno aff
Patricia R. Melvin, Todd Bertrand, David A. Crawford, Keith R. Berend

Bibliographic record

VenueSurgical Technology Online · 2024
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsnot available
Fundersnot available
KeywordsPeriprostheticMedicineSurgeryTotal hip arthroplastyFemurRadiographyFemoral canalArthroplasty

Abstract

fetched live from OpenAlex

INTRODUCTION: Utilization of the direct anterior approach (DAA) for total hip arthroplasty (THA) has been steadily increasing in recent years. While the DAA may offer some benefits compared to other approaches, there are still risks involved including relatively higher rates of periprosthetic femur fractures, especially when combined with cementless femoral stem use. The purpose of this study is to evaluate the early postoperative femoral complications with a short triple-wedge tapered stem used in primary THA via a DAA. MATERIALS AND METHODS: A retrospective review was conducted of the arthroplasty registry of our institution from April 2022 to August 2023 to identify patients who underwent a primary THA via a DAA with the Short Medacta Stem (SMS) (Medacta International, Castel San Pietro, Switzerland). Patients were excluded if the stem was used for a revision surgery, they were within 90 days of surgery, or they refused research consent. Inclusion criteria was met in 262 patients (302 hips). Data was collected after reviewing the chart, and reports and radiographic measurements, including Dorr type and canal fit ratios, were obtained from preoperative and postoperative radiographs, respectively. RESULTS: A total of 302 total hips were included, 161 patients were male (53.3%) and 141 were female (46.7%), with an average age of 66.5 years (27-88, +/- 10.7 years). Average follow up was 0.3 years (range, 0.05-1.71 years). The majority of patients had a Dorr B femur (81.7%). The Median stem size used was an 8 (range, 2-15), and 89.4% of those had a collar. Average canal fill ratio was 0.83 (range, 0.43-0.98, +/- 0.07). Overall, there were two Vancouver B2a periprosthetic femoral shaft fractures (0.66%) that required revision surgery to a modular stem. In addition, there were two Vancouver Ag greater trochanteric fractures (0.66%) with acceptable alignment that did not require revision surgery. Demographic information about the patients with femoral complications is summarized in Table I. Average age of patients with femoral complications was 69.5 years, with an average canal fit ratio of 0.88. CONCLUSION: We found that the triple-wedge implant had a low rate of early femoral complication in primary THA from an anterior approach and is safe for use in THA from a DAA. More follow up is needed to evaluate continuing implant survivorship and patient outcomes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.816
Threshold uncertainty score0.741

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.267
Teacher spread0.258 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueSurgical Technology OnlineSame topicOrthopaedic implants and arthroplastyFrench-language works237,207