MétaCan
Menu
Back to cohort
Record W4396919429 · doi:10.1016/j.nima.2024.169446

Identification and recovery of ATLAS18 strip sensors with high surface static charge

2024· article· en· W4396919429 on OpenAlexafffund
E. J. Staats, A. A. Affolder, H. P. Beck, A. J. Bevan, Z. Chen, I. Dawson, Abhishek Y. Deshmukh, A. Dowling, Damir Duvnjak, V. Fadeyev, P. Federičová, J. Fernández-Tejero, A. Fournier, Neil Guerrero González, C. E. Jessiman, S. Kachiguin, J. S. Keller, C. Klein, T. Koffas, J. Kroll, J. Kvasnička, V. Latoňová, F. Martinez-Mckinney, M. Mikeštíková, P. S. Miyagawa, Sandra A. O’Toole, Q. Paddock, L. Poley, E.A. Slavíková, B. Stelzer, Petr Tůma, M. Ullán, Y. Unno, C. I. Westbrook, S. Zenz

Bibliographic record

VenueNuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · 2024
Typearticle
Languageen
FieldPhysics and Astronomy
TopicParticle Detector Development and Performance
Canadian institutionsSimon Fraser UniversityCarleton University
FundersAgencia Estatal de InvestigaciónNatural Sciences and Engineering Research Council of CanadaScience and Technology Facilities CouncilForskningsrådet om Hälsa, Arbetsliv och VälfärdCERNU.S. Department of Energy
KeywordsIdentification (biology)Charge (physics)Surface chargeSurface (topology)Materials scienceComputer scienceAcousticsPhysicsGeometryMathematicsBiology

Abstract

fetched live from OpenAlex

The new all-silicon Inner Tracker (ITk) is being constructed by the ATLAS collaboration to track charged particles produced at the High-Luminosity LHC. The outer portion of the ITk detector will include nearly 18,000 highly segmented and radiation hard silicon strip sensors (ATLAS18 design). Throughout the production of 22,000 sensors, the strip sensors are subjected to a comprehensive suite of mechanical and electrical tests as part of the Quality Control (QC) program. In a large fraction of the batches delivered to date, high surface electrostatic charge has been measured on both the sensors and the plastic sheets between which the sensors are packaged for shipping and handling rigidity. Aggregate data from across QC sites indicate a correlation between observed electrical failures and the sensor/plastic sheet charge build up. To mitigate these issues, the QC testing sites introduced recovery techniques involving UV light or flows of ionizing gas. Significant modifications to sensor handling procedures were made to prevent subsequent build up of static charge. This publication details a precise description of the issue, a variety of sensor recovery techniques, and trend analyses of sensors initially failing electrical tests (IV, strip scan, etc.).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.035
GPT teacher head0.348
Teacher spread0.314 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueNuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated EquipmentSame topicParticle Detector Development and PerformanceFrench-language works237,207