MétaCan
Menu
Back to cohort
Record W4396937408 · doi:10.3390/en17102373

Experimental Investigation of Parameters Influencing the Formation of Dry Bands and Related Electric Field

2024· article· en· W4396937408 on OpenAlexafffund
Marc‐Alain Andoh, C. Volat

Bibliographic record

VenueEnergies · 2024
Typearticle
Languageen
FieldMaterials Science
TopicHigh voltage insulation and dielectric phenomena
Canadian institutionsUniversité du Québec à Chicoutimi
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsInsulator (electricity)Substrate (aquarium)Materials scienceComposite materialPollutionLayer (electronics)

Abstract

fetched live from OpenAlex

This paper presents an experimental investigation conducted to determine the influence of parameters such as the ambient temperature, pollution level, and substrate material on the formation of dry bands on polluted layers. To investigate these parameters, we applied a simplified insulator geometry, developed in our previous work, to experimentally control the complex process of dry band formation on a polluted surface. The simple geometry of the experimental model enabled the use of Plexiglas, RTV, and glass as construction substrate materials. RTV and glass were used to simulate a composite and ceramic insulator surface, respectively. Moreover, an electrooptic (EO) probe enabled the measurement of the axial E-field evolution at the surface of the dry band during dry band formation. The results indicated that the substrate material, ambient temperature, and pollution level substantially influence dry band formation. The effects of the first two parameters are directly associated with heat transfer phenomena in the substrate material and at the ambient air/substrate interface. The effect of the third parameter is associated with absorption and evaporation of the pollution layer. In addition, the appearance of the dry band can be clearly identified by a rapid increase in both the pollution layer resistance and the axial E-field in the dry band area. The value of the axial E-field is influenced primarily by the width of the dry band and by the pollution layer resistance, which is directly dependent on the humidification duration. Finally, because most of the results obtained herein were in accordance with those in the literature, we conclude that the proposed experimental model may provide an effective and inexpensive testing method for developing new materials and solutions for improving the dielectric performance of insulators used in polluted environments. Similarly, the simple geometry of the experimental model and the ability to easily control the experimental parameters may enable this tool to validate the results of various numerical models in studies of the thermoelectrical behavior of polluted insulators.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.230
Teacher spread0.220 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueEnergiesSame topicHigh voltage insulation and dielectric phenomenaFrench-language works237,207