MétaCan
Menu
Back to cohort
Record W4396982172 · doi:10.1109/tbme.2024.3401681

Hybrid Hydrogel-Magnet Actuated Capsule for Automatic Gut Microbiome Sampling

2024· article· en· W4396982172 on OpenAlexafffund
Yung Priscilla Lai, Taeyoung Lee, Daniel Sieben, Lyle Gauthier, Jaekwang Nam, Eric Diller

Bibliographic record

VenueIEEE Transactions on Biomedical Engineering · 2024
Typearticle
Languageen
FieldMedicine
TopicGastrointestinal motility and disorders
Canadian institutionsUniversity of Toronto
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsCapsuleGut microbiomeMagnetMicrobiomeSampling (signal processing)Biomedical engineeringMaterials scienceComputer scienceBiologyMedicineEngineeringMechanical engineeringBioinformaticsDetectorTelecommunications

Abstract

fetched live from OpenAlex

OBJECTIVE: Non-invasive, pill-sized capsules can provide intestinal fluid sampling to easily retrieve site-specific gut microbiome samples for studies in nutrition and chronic diseases. However, capsules with both automatic sampling and active locomotion are uncommon due to limited onboard space. This paper presents a novel hybrid hydrogel-magnet actuated capsule featuring: i) pH-responsive hydrogels that will automatically trigger fluid sampling at an environmental pH of 6 and ii) active locomotion by an external rotating magnetic field. METHOD: Two capsule designs were fabricated (Design A: 31 μL sampling volume with dimensions 8 mm × 19 mm, Design B: 41 μL sampling volume with dimensions 8 mm × 21 mm). They were immersed in simulated gastric (pH = 1.2) and simulated intestinal fluid (pH = 6.8) to test for automatic intestinal fluid sampling. An external rotating magnetic field was applied to test for active locomotion. Finally, seal tests were performed to demonstrate sample contamination mitigation. RESULTS: Preliminary experiments showed that sampling occurred quickly and automatically in simulated intestinal fluid at 6-15 hours, active locomotion via rotation, rolling, and tumbling were possible at magnetic field magnitudes 10 mT, oil piston seals were better at mitigating sample contamination than water piston seals, and minimum o-ring seal pressures limits of 1.95 and 1.69 kPa for Design A and B respectively were sufficient against intra-abdominal pressures. SIGNIFICANCE: This work presents the ability to impart capsule multi-functionality in a compact manner without onboard electronics or external triggering for sampling.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.935
Threshold uncertainty score0.877

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.258
Teacher spread0.242 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueIEEE Transactions on Biomedical EngineeringSame topicGastrointestinal motility and disordersFrench-language works237,207